Datasheet
Application
Application | universal evaluation and display for all physical units which can be derived from pulse sequences |
---|
Electrical data
Frequency AC [Hz] | 50…60 |
---|---|
Operating voltage tolerance [%] | 33…58 |
Operating voltage [V] | 230 / 115 AC / 24 DC |
Current consumption [mA] | 120 (18 V); 95 (24 V); 80 (30 V) |
Auxiliary energy for sensors DC [V] | 24; (±15 %, 150 mA) |
Inputs / outputs
Number of inputs and outputs | Number of analogue outputs: 1 |
---|
Outputs
Number of analogue outputs | 1 |
---|---|
Analogue current output [mA] | 4…20 |
Analogue voltage output [V] | 0…10 |
Operating conditions
Ambient temperature [°C] | 0…45 |
---|---|
Storage temperature [°C] | -25…75 |
Protection | IP 65; (on the front) |
Protection rating terminals | IP 20 |
Tests / approvals
EMC |
|
---|
Mechanical data
Weight [g] | 580.8 |
---|---|
Materials | Noryl UL94-V-0 |
Displays / operating elements
Display |
|
---|
Electrical connection
Connection | screw terminals, DC: 10 x …1.5 mm² |
---|