€0.00
The price is not final. Please check with the manager!
IGB2005-BBOA/SL/LS-100AK/RT
- With combined AC/DC output stage
- Two-wire technology
- Wide operating temperature range
- Robust metal housing for use in harsh industrial environments
-
Ask a Question
Datasheet
Product characteristics
Output function | normally closed |
---|
Sensing range [mm] | 5 |
---|
Housing | threaded type |
---|
Dimensions [mm] | M18 x 1 |
---|
Electrical data
Operating voltage [V] | 20…250 AC/DC |
---|
Protection class | I |
---|
Reverse polarity protection | no |
---|
Outputs
Output function | normally closed |
---|
Max. voltage drop switching output DC [V] | 6 |
---|
Max. voltage drop switching output AC [V] | 6.5 |
---|
Minimum load current [mA] | 5 |
---|
Max. leakage current [mA] | 2.5 (250 V AC) / 1.3 (110 V AC) / 0.8 (24 V DC) |
---|
Permanent current rating of switching output AC [mA] | 250; (350 (…50 °C)) |
---|
Permanent current rating of switching output DC [mA] | 100 |
---|
Short-time current rating of switching output [mA] | 2200; (20 ms / 0,5 Hz) |
---|
Switching frequency AC [Hz] | 25 |
---|
Switching frequency DC [Hz] | 100 |
---|
Short-circuit proof | no |
---|
Overload protection | no |
---|
Detection zone
Sensing range [mm] | 5 |
---|
Real sensing range Sr [mm] | 5 ± 10 % |
---|
Operating distance [mm] | 0…4.05 |
---|
Accuracy / deviations
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 |
---|
Hysteresis [% of Sr] | 3…15 |
---|
Switch point drift [% of Sr] | -10…10 |
---|
Operating conditions
Ambient temperature [°C] | -25…80 |
---|
Protection | IP 67 |
---|
Tests / approvals
EMC | EN 60947-5-2 | | EN 55011 | class B |
|
---|
MTTF [years] | 609 |
---|
UL approval | Ta | 0…40 °C | Enclosure type | Type 1 | power supply | Hazardous voltage | File number UL | E174191 |
|
---|
Mechanical data
Weight [g] | 63 |
---|
Housing | threaded type |
---|
Mounting | flush mountable |
---|
Dimensions [mm] | M18 x 1 |
---|
Thread designation | M18 x 1 |
---|
Materials | brass white bronze coated; PC |
---|
Displays / operating elements
Display | switching status | 1 x LED, red |
|
---|
Electrical connection
Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
---|
Remarks
Remarks | Recommendation: Check the safe functioning of the unit after a short circuit. |
|
---|
Pack quantity | 1 pcs. |
---|
Electrical connection – plug
| Connector: 1 x 1/2″; coding: C |
---|