Datasheet
Product characteristics
Resolution | 8192 steps; 13 bit |
---|---|
Communication interface | CAN |
Shaft design | solid shaft |
Shaft diameter [mm] | 6 |
Application
Function principle | absolute |
---|---|
Revolution type | singleturn |
Electrical data
Operating voltage [V] | 9…36 DC |
---|---|
Current consumption [mA] | < 250 |
Reverse polarity protection | yes |
Outputs
Short-circuit protection | yes |
---|---|
Code | binary |
Measuring/setting range
Resolution | 8192 steps; 13 bit |
---|
Accuracy / deviations
Accuracy | ± 1 LSB |
---|
Software / programming
Parameter setting options | CAN parameter; scaling; preset; Baud rate; direction of rotation; address |
---|---|
Addressing | address selector switch; Software |
Interfaces
Communication interface | CAN |
---|
Protocol | CANopen; DSP – 406 |
---|
Operating conditions
Ambient temperature [°C] | -40…70 |
---|---|
Protection | IP 66; (on the housing: IP 67; on the shaft: IP 66) |
Tests / approvals
Shock resistance |
|
||
---|---|---|---|
Vibration resistance |
|
Mechanical data
Weight [g] | 689.2 | |
---|---|---|
Dimensions [mm] | Ø 58 / L = 90.5 | |
Materials | aluminium | |
Max. revolution, mechanical [U/min] | 6000 | |
Max. starting torque [Nm] | 1 | |
Reference temperature torque [°C] | 20 | |
Shaft design | solid shaft | |
Shaft diameter [mm] | 6 | |
Shaft material |
|
|
Max. shaft load axial (at the shaft end) [N] | 10 | |
Max. shaft load radial (at the shaft end) [N] | 20 | |
Fixing flange | synchro-flange |
Electrical connection
terminal strip in the terminal chamber: ; Maximum cable length: 25 m; 100 m (500 kb/s) |