Main
Range of product Modicon LMC058
Product or component type Motion controller
Product specific application
Discrete I/O number 42
Battery type 3 V CR2477M lithium battery
Complementary
Discrete input number 10 for fast input
12 for input
4 for regular input
Discrete input logic Sink for fast input
Sink for regular input
Source for input
Discrete input voltage 24 V
Discrete input voltage type DC
Analogue input number 4
Analogue input type Current: 0…20 mA
Current: 4…20 mA
Voltage: +/- 10 V
Analogue input resolution 12 bits
Voltage state 1 guaranteed >= 15 V for fast input
>= 15 V for fast output
>= 15 V for regular input
Voltage state 0 guaranteed <= 5 V for fast input
<= 5 V for fast output
<= 5 V for regular input
Discrete input current 4 mA for fast input
4 mA for regular input
Input impedance 6 kOhm for fast input
6 kOhm for regular input
Configurable filtering time 0 ms for fast input/regular input and fast output
1.5 ms for fast input/regular input and fast output
12 ms for fast input/regular input and fast output
4 ms for fast input/regular input and fast output
Anti bounce filtering 2 µs…4 ms configurable fast input/regular input and fast output
Maximum cable distance between devices <30 m for fast input
Insulation Between channels and internal logic at 500 V AC
Non-insulated between channels
Discrete output number 12 output
4 fast output
Discrete output logic Source
Discrete output voltage 24 V DC
Output voltage limits 19.2…28.8 V
Discrete output current 4 mA for fast output
[Us] rated supply voltage 24 V DC for embedded expert modules power
Supply voltage limits 20.4…28.8 V
[In] rated current 0.04 A for embedded expert modules power
10 A for I/O power segment
0.3 A for main supply
Peak current 100 kA (duration = <= 70 s) for main supply
25 kA (duration = <= 500 s) for I/O power segment
50 kA (duration = <= 150 s) for embedded expert modules power
1.2 A (duration = > 70 s) for main supply
Power consumption in W 14.14 W
Memory type 128 MB flash
64 MB RAM
Realtime clock Without any user calibration clock, clock drift < 30 s/month at 25 °C
With user calibration clock, clock drift <= 6 s/month
Data backed up Battery variables of type retain and retain persistent
Battery life 1.5 year(s)
Integrated connection type 1 isolated serial link with female RJ45 connectorModbus with master/slave RTU/ASCII or character mode ASCII, physical interface: RS232/RS485, transmission rate: 300…115200 bps
1 CAN port with male SUB-D 9 connectorCANmotion bus or CANopen with master
1 CAN port with male SUB-D 9 connectorCANopen with master
1 encoder with female SUB-D 15 connector
1 isolated serial link with female RJ45 connectorEthernet Modbus TCP/IP with slave, physical interface: 10BASE-T/100BASE-TX
1 isolated serial link with mini B USB connector, transmission rate: 480 Mbit/s
1 isolated serial link with USB type A connector, transmission rate: 480 Mbit/s
2 free slots PCI
Transmission rate 10 kbit/s for bus length of 5000 m for CANopen
1000 kbit/s for bus length of 4 m for CANopen
125 kbit/s for bus length of 500 m for CANopen
20 kbit/s for bus length of 2500 m for CANopen
250 kbit/s for bus length of 250 m for CANopen
50 kbit/s for bus length of 1000 m for CANopen
500 kbit/s for bus length of 100 m for CANopen
800 kbit/s for bus length of 25 m for CANopen
Counting input number 8 counting input(s) at 200 kHz
Local signalling 1 LED for CAN0 STS
1 LED green/red for CAN1 STS
1 LED green/yellow for MBS COM
1 LED per channel for APP0
1 LED red for APP1
Marking CE
Mounting support Symmetrical DIN rail
Width 237.5 mm
Height 99 mm
Depth 85 mm
Net weight 0.77 kg
Environment
Standards UL 508
IEC 61131-2
CSA C22.2 No 213
CSA C22.2 No 142
Product certifications cULus
CSA
C-Tick
GOST-R
Ambient air temperature for operation 0…55 °C without derating (horizontal installation)
0…60 °C with derating factor (horizontal installation)
0…50 °C (vertical installation)
Ambient air temperature for storage -25…70 °C
Relative humidity 5…95 % without condensation
IP degree of protection IP20 conforming to IEC 61131-2
Pollution degree 2 conforming to IEC 60664
Operating altitude 0…2000 m
Storage altitude 0…3000 m
Vibration resistance 1 gn at 8.4…150 Hz on DIN rail
3.5 mm at 5…8.4 Hz on DIN rail
Shock resistance 15 gn for 11 ms
Electromagnetic compatibility Electrostatic discharge immunity test – test level: 8 kV (on contact) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test – test level: 4 kV (on air) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields – test level: 1 V/m (2…2.7 GHz) conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields – test level: 10 V/m (80…2000 MHz) conforming to EN/IEC 61000-4-3
Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4
Surge immunity test – test level: 0.5 kV (differential mode) conforming to EN/IEC 61000-4-5
Surge immunity test – test level: 1 kV (common mode) conforming to EN/IEC 61000-4-5
Conducted RF disturbances conforming to EN/IEC 61000-4-6
Conducted and radiated emissions conforming to CISPR 11
Disturbance radiated/conducted CISPR 11
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 13.200 cm
Package 1 Width 15.800 cm
Package 1 Length 37.000 cm
Package 1 Weight 944.000 g
Unit Type of Package 2 S04
Number of Units in Package 2 6
Package 2 Height 30.000 cm
Package 2 Width 40.000 cm
Package 2 Length 60.000 cm
Package 2 Weight 6.376 kg
Contractual warranty
Warranty 18 months