Datasheet
| Usage | Can only be used in the EFI system network, e.g., with a Flexi Soft safety controller |
| Application | Indoor |
| Protective field range | 7 m |
| Collision protection field range | 15 m (on reference target) 1) |
| Distance measuring range | 49 m |
| Number of simultaneously monitored protective fields | 2 1) |
| Type of field set | Triple field sets, dual field sets |
| Number of field sets | 16 2) |
| Number of fields | 32 |
| Number of monitoring cases | 32 |
| Scanning angle | 190° |
| Resolution (can be configured) | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm |
| Angular resolution | 0.25° |
| Response time | 120 ms 3) |
| Protective field supplement | 100 mm |
| Number of multiple samplings | 2 … 16, configurable |
| Delay of automatic reset | 2 s … 60 s, configurable |