Datasheet
Product characteristics
| Output function | normally open |
|---|---|
| Sensing range [mm] | 20…70 |
| Housing | cylindrical |
| Dimensions [mm] | Ø 100 / L = 40 |
Electrical data
| Frequency AC [Hz] | 47…63 |
|---|---|
| Operating voltage [V] | 90…250 AC |
| Protection class | II |
| Reverse polarity protection | no |
Outputs
| Output function | normally open |
|---|---|
| Max. voltage drop switching output AC [V] | 11 |
| Minimum load current [mA] | 15 |
| Max. leakage current [mA] | 6 |
| Permanent current rating of switching output AC [mA] | 200; (250 (…50 °C)) |
| Short-time current rating of switching output [mA] | 1500; (10 ms / 0,5 Hz) |
| Switching frequency AC [Hz] | 5 |
| Short-circuit proof | no |
| Overload protection | no |
Detection zone
| Sensing range [mm] | 20…70 |
|---|---|
| Sensing range adjustable | yes |
| Factory setting sensing range [mm] | 70 |
| Real sensing range Sr [mm] | 70 ± 10 % |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
|---|---|
| Hysteresis [% of Sr] | < 15 |
| Switch point drift [% of Sr] | -15…15 |
Operating conditions
| Ambient temperature [°C] | -20…70 |
|---|---|
| Protection | IP 65 |
Tests / approvals
| EMC |
|
|---|
Mechanical data
| Weight [g] | 676 |
|---|---|
| Housing | cylindrical |
| Mounting | non-flush mountable |
| Type of mounting | with mounting plate |
| Dimensions [mm] | Ø 100 / L = 40 |
| Materials | PBT; aluminium anodised |
Displays / operating elements
| Display |
|
|---|
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
|---|
Remarks
| Remarks |
|
|
|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | Cable: 2 m, PVC; 2 x 0.5 mm² |
|---|