Product characteristics
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range |
|
-50…400 mbar |
-20…160.6 inH2O |
-5…40 kPa |
|
| Process connection |
threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop. |
Application
| Special feature |
Gold-plated contacts |
| Application |
flush mountable for the food and beverage industry |
| Media |
viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature [°C] |
-25…150 |
| Min. bursting pressure |
|
30000 mbar |
12044 inH2O |
3000 kPa |
|
| Pressure rating |
|
8000 mbar |
3200 inH2O |
800 kPa |
|
| Vacuum resistance [mbar] |
-1000 |
| Type of pressure |
relative pressure; vacuum |
| No dead space |
yes |
Electrical data
| Min. insulation resistance [MΩ] |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Integrated watchdog |
yes |
2-wire
| Operating voltage [V] |
20…30 DC |
| Current consumption [mA] |
3.5…21.5 |
| Power-on delay time [s] |
< 1 |
3-wire
| Operating voltage [V] |
18…30 DC |
| Current consumption [mA] |
5…45; (430 bei max. Laststrom) |
| Power-on delay time [s] |
< 0.5 |
Inputs / outputs
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; IO-Link |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20, invertible; (scalable) |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
3-wire
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
100 |
| Switching frequency DC [Hz] |
125 |
| Max. load [Ω] |
(Ub – 10 V) / 21,5 mA; 650 Ω (Ub = 24 V) |
Measuring/setting range
| Measuring range |
|
-50…400 mbar |
-20…160.6 inH2O |
-5…40 kPa |
|
| Set point SP |
|
-49.4…400 mbar |
-19.8…160.6 inH2O |
-4.94…40 kPa |
|
| Reset point rP |
|
-50…399.4 mbar |
-20.1…160.3 inH2O |
-5…39.94 kPa |
|
| Analogue start point |
|
-50…320 mbar |
-20.1…128.5 inH2O |
-5…32 kPa |
|
| Analogue end point |
|
30…400 mbar |
12…160.6 inH2O |
3…40 kPa |
|
| Min. difference between SP and rP |
|
0.6 mbar |
0.3 inH2O |
0.06 kPa |
|
| In steps of |
|
0.1 mbar |
0.1 inH2O |
0.01 kPa |
|
| Factory setting |
|
|
SP1 =100 mbar |
rP1 = 92 mbar |
|
|
SP2 = 300 mbar |
rP2 = 292 mbar |
|
|
ASP = 0.00 mbar |
AEP = 400 mbar |
|
|
dAP = 2.00 s |
dAA =2.00 s |
|
Temperature monitoring
| Measuring range |
|
Accuracy / deviations
| Switch point accuracy [% of the span] |
< ± 0,2; (DIN EN IEC 62828-1; Turn down 1:1) |
| Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span] |
< ± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1) |
| Linearity deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
| Hysteresis deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
| Long-term stability [% of the span] |
< ± 0,1; (Turn down 1:1; per year) |
| Total deviation over temperature range |
|
Temperature range |
total deviation |
|
-25…15 °C |
Characteristics deviation ± 0,1 % der Spanne / 10 K |
|
15…80 °C |
Characteristics deviation |
|
80…150 °C |
Characteristics deviation ± 0,15 % der Spanne / 10 K |
|
| Notes on the accuracy / deviation |
for further details see section Diagrams and graphs |
Temperature monitoring
| Accuracy [K] |
± 2,5+ (0,08 x ( Umgebungstemperatur – Mediumtemperatur )) |
| Repeatability [K] |
± 0,2 |
| Resolution [K] |
0.2 |
Response times
| Damping process value dAP [s] |
0…99.99 |
| Damping for the analogue output dAA [s] |
0…99.99 |
2-wire
| Step response time analogue output [ms] |
30 |
3-wire
| Min. response time of switching output (dAP) [ms] |
3 |
| Step response time analogue output [ms] |
7 |
Temperature monitoring
| Dynamic response T05 / T09 [s] |
< 35 / < 135; (DIN EN 60751 water ; > 0,9 m/s) |
Interfaces
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A) |
| SIO mode |
yes |
| Required master port type |
A |
| Min. process cycle time [ms] |
5.6 |
| IO-Link resolution pressure [mbar] |
0.02 |
| IO-Link resolution temperature [K] |
0.2 |
| IO-Link process data (cyclical) |
|
function |
bit length |
|
pressure |
32 |
|
temperature |
32 |
|
device status |
4 |
|
binary switching information |
2 |
|
| IO-Link functions (acyclical) |
application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter |
| Supported DeviceIDs |
|
Type of operation |
DeviceID |
|
Default |
1189 d |
|
Operating conditions
| Ambient temperature [°C] |
-25…80 |
| Storage temperature [°C] |
-40…100 |
| Protection |
IP 67; IP 68; IP 69K |
Tests / approvals
| EMC |
|
| Shock resistance |
|
DIN EN 60068-2-27 |
50 g (11 ms) |
|
| Vibration resistance |
|
DIN EN 60068-2-6 |
20 g (10…2000 Hz) |
|
| MTTF [years] |
214 |
| Note on approval |
|
factory certificate available as download at www.factory-certificate.ifm |
|
| UL approval |
|
UL Approval no. |
J049 |
|
File number UL |
E174189 |
|
Mechanical data
| Weight [g] |
395 |
| Materials |
stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
| Materials (wetted parts) |
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
| Min. pressure cycles |
100 million |
| Tightening torque [Nm] |
20 |
| Process connection |
threaded connection G 1 external thread sealing cone Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop. |
Displays / operating elements
| Display |
|
Display unit |
LED, green |
|
switching status |
LED, yellow |
|
function display |
alphanumeric display, 4-digit |
|
measured values |
alphanumeric display, 4-digit |
|
| Display unit |
mbar; kPa; inH2O; mmWS |
Electrical connection
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |
Diagrams and graphs
|
|
|
X
|
temperature |
|
Y
|
total deviation |
|