Datasheet
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|---|
| Process connection | diameter Ø 8 mm |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Installation | Recommended for pipe diameters; ( 15…400 mm) |
| Media | air |
| Medium temperature [°C] | -20…100 |
| Pressure rating [bar] | 50 |
| Pressure rating [Mpa] | 5 |
| MAWP (for applications according to CRN) [bar] | 50 |
Electrical data
| Operating voltage [V] | 18…30 DC; (to SELV/PELV) |
|---|---|
| Current consumption [mA] | < 100 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 10 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 250 |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (scalable) |
| Max. load [Ω] | 350 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Frequency of the output [Hz] | 0…1000 |
Measuring/setting range
| Probe length L [mm] | 200 | |
|---|---|---|
| Operating mode | relative; absolutely gaseous; (absolute: reference measurement recommended) | |
| Display range [m/s] | 0…36 | |
| Resolution [m/s] | 0.2 | |
| Note on factory setting |
|
|
| Set point SP [m/s] | 2…30 | |
| Reset point rP [m/s] | 0.6…28.6 | |
| Analogue start point ASP [m/s] | 0…24 | |
| Analogue end point AEP [m/s] | 6…30 | |
| Frequency end point, FEP [m/s] | 6.6…30 | |
| Frequency at the end point FRP [Hz] | 100…1000 |
| Setting range [m/s] | 0…30 |
|---|---|
| Greatest sensitivity [m/s] | 0.6…30 |
| Setting range [m/s] | 0…60 |
|---|---|
| Greatest sensitivity [m/s] | 0.6…30 |
| Measuring range [°C] | -20…100 |
|---|---|
| Resolution [°C] | 0.2 |
Accuracy / deviations
| Repeatability | ± (3 % MW + 0,6 % MEW) |
|---|
| Accuracy | ± (10 % MW + 2 % MEW); (reference conditions: DN50; Inside diameter 51 mm; within the range of maximum sensitivity: 20 °C / < 6 bar; Insertion depth: 15 mm; inlet pipe length: 2.5 m; standard velocity to DIN ISO 2533 at the sensor tip) |
|---|---|
| Repeatability | ± (3 % MW + 0,6 % MEW) |
| Temperature drift | ± 0,005 K/°C |
|---|---|
| Accuracy [K] | ± 2 / + 8; (flow velocity > 20 % VMR and 20 °C: ± 2) |
Response times
| Response time [s] | 7 |
|---|
| Dynamic response T05 / T09 [s] | 30 (T09); (flow velocity: ≥ 10 m/s) |
|---|
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour |
|---|
Interfaces
| Communication interface | IO-Link | ||||||
|---|---|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||||
| IO-Link revision | 1.1 | ||||||
| SDCI standard | IEC 61131-9 | ||||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||
| SIO mode | yes | ||||||
| Required master port type | A | ||||||
| Process data analogue | 2 | ||||||
| Process data binary | 2 | ||||||
| Min. process cycle time [ms] | 3 | ||||||
| Supported DeviceIDs |
|
Operating conditions
| Ambient temperature [°C] | -40…80 |
|---|---|
| Storage temperature [°C] | -40…100 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC |
|
||||
|---|---|---|---|---|---|
| Shock resistance |
|
||||
| Vibration resistance |
|
||||
| MTTF [years] | 131 | ||||
| UL approval |
|
Mechanical data
| Weight [g] | 343.8 |
|---|---|
| Materials | stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30 |
| Materials (wetted parts) | stainless steel (1.4404 / 316L) |
| Process connection | diameter Ø 8 mm |
Displays / operating elements
| Display |
|
|---|
Remarks
| Remarks |
|
||
|---|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
|---|