Datasheet
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|---|
| Process connection | threaded connection 1″ NPT DN25 |
| Measuring range [psi] | -15…232 |
|---|
Application
| Application | for industrial applications |
|---|---|
| Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2); compressed air |
| Medium temperature [°F] | 14…140 |
| Min. bursting pressure [psi] | 928 |
| Pressure rating [psi] | 232 |
| MAWP (for applications according to CRN) [bar] | 10.5 |
Electrical data
| Operating voltage [V] | 18…30 DC; (to SELV/PELV) |
|---|---|
| Current consumption [mA] | < 80 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 1 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
|---|
Inputs
| Inputs | counter reset |
|---|
Outputs
| Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
|---|---|
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 150; (per output) |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (scalable) |
| Max. load [Ω] | 500 |
| Pulse output | consumed quantity meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range |
|
|||
|---|---|---|---|---|
| Display range |
|
|||
| Resolution |
|
|||
| Set point SP |
|
|||
| Reset point rP |
|
|||
| Analogue start point ASP |
|
|||
| Analogue end point AEP |
|
|||
| Low flow cut-off LFC |
|
|||
| In steps of |
|
| Measuring range [psi] | -15…232 |
|---|---|
| Display range [psi] | -15…290 |
| Resolution [psi] | 1 |
| Set point SP [psi] | -13…232 |
| Reset point rP [psi] | -15…231 |
| Analogue start point [psi] | -15…186 |
| Analogue end point [psi] | 32…232 |
| In steps of [psi] | 1 |
| Measuring range |
|
||
|---|---|---|---|
| Display range |
|
||
| Set point SP |
|
||
| Pulse value |
|
||
| In steps of |
|
||
| Pulse length [s] | 0.007…2 |
| Measuring range |
|
||
|---|---|---|---|
| Display range |
|
||
| Resolution |
|
||
| Set point SP |
|
||
| Reset point rP |
|
||
| Analogue start point |
|
||
| Analogue end point |
|
||
| In steps of |
|
Accuracy / deviations
| Temperature coefficient [1/K] | ± 0,07 % MW |
|---|---|
| Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW); (at medium temperature 73 °F) |
| Repeatability | ± (0,4 % MW + 0,1 % MEW) |
| Repeatability [% of the final value] | ± 0,2 |
|---|---|
| Characteristics deviation [% of the final value] | < ± 0,5; (BFSL = Best Fit Straight Line) |
| Greatest TEMPCO of the span [% MEW / 10 K] | ± 0,3 |
| Greatest TEMPCO of the zero point [% MEW / 10 K] | ± 0,1 |
| Accuracy [K] | ± 0,5; (medium flow in the limit area of the flow measurement range) |
|---|
Response times
| Response time [s] | 0.1; (dAP = 0) |
|---|---|
| Damping process value dAP [s] | 0…5 |
| Response time [s] | 0.05 |
|---|
| Dynamic response T05 / T09 [s] | T09 = 0,5 |
|---|
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser |
|---|
Interfaces
| Communication interface | IO-Link | ||||
|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 CDV | ||||
| Profiles | Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000) | ||||
| SIO mode | yes | ||||
| Required master port type | A | ||||
| Process data analogue | 8 | ||||
| Process data binary | 2 | ||||
| Min. process cycle time [ms] | 7.2 | ||||
| Supported DeviceIDs |
|
Operating conditions
| Ambient temperature [°F] | 32…140 |
|---|---|
| Storage temperature [°C] | -4…185 |
| Max. relative air humidity [%] | 90 |
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC |
|
||||
|---|---|---|---|---|---|
| Vibration resistance |
|
||||
| MTTF [years] | 183 | ||||
| UL approval |
|
||||
| Pressure Equipment Directive | Sound engineering practice; can be used for stable gases fluid group 2 |
Mechanical data
| Weight [g] | 1608.8 |
|---|---|
| Materials | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM |
| Materials (wetted parts) | stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate |
| Process connection | threaded connection 1″ NPT DN25 |
Displays / operating elements
| Display |
|
|---|
Remarks
| Remarks |
|
||||
|---|---|---|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | Connector: 1 x M12; coding: A |
|---|