Datasheet
Product characteristics
| Process connection | G 1 DN25 external thread |
|---|
Application
| Special feature | Gold-plated contacts | ||
|---|---|---|---|
| Media | ultra-pure water; water; hydrous media | ||
| Note on media |
|
||
| Medium temperature |
|
||
| Min. bursting pressure |
|
||
| Pressure rating |
|
||
| Vacuum resistance [mbar] | -1000 |
Electrical data
| Operating voltage [V] | 18…32 DC; (to SELV/PELV) |
|---|---|
| Current consumption [mA] | < 75 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 5 |
| Measuring principle | ultrasonic |
Inputs
| Inputs | counter reset |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | analogue signal; pulse signal; analogue signal; IO-Link; frequency signal; diagnostic signal; totaliser switching signal |
| Electrical design | PNP/NPN |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 100 |
| Switching frequency DC [Hz] | 0…10000 |
| Analogue current output [mA] | 4…20 |
| Max. load [Ω] | 500 |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range |
|
||||
|---|---|---|---|---|---|
| Display range |
|
||||
| Resolution |
|
||||
| Set point SP |
|
||||
| Reset point rP |
|
||||
| Analogue start point ASP |
|
||||
| Analogue end point AEP |
|
||||
| Low flow cut-off LFC |
|
||||
| Frequency end point, FEP |
|
||||
| Frequency at the end point FRP [Hz] | 1…10000 |
| Pulse length [s] | 0.002…2 |
|---|---|
| Pulse value | 0.02…99990000 l; 0.005…26414563.515 gal |
| Measuring range |
|
||
|---|---|---|---|
| Display range |
|
||
| Resolution |
|
||
| Set point SP |
|
||
| Reset point rP |
|
||
| Analogue start point |
|
||
| Analogue end point |
|
||
| Frequency start point, FSP |
|
||
| Frequency end point, FEP |
|
||
| Frequency at the end point FRP [Hz] | 1…10000 |
Accuracy / deviations
| Accuracy (in the measuring range) | ± (1,0 % MW + 0,5 % MEW) |
|---|---|
| Repeatability | ± 0,2 % MEW |
| Accuracy [K] | ± 2,5 (Q > 5 % MEW) |
|---|---|
| Temperature coefficient [% of the span / 10 K] | 0,2 |
Response times
| Response time [s] | < 0.25; (dAP = 0, T09) |
|---|---|
| Damping process value dAP [s] | 0…5 |
| Dynamic response T05 / T09 [s] | 5,7 / 86 |
|---|
Software / programming
| Diagnostic functions | direction of flow detection; signal quality |
|---|
Interfaces
| Communication interface | IO-Link | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||||||||||||
| IO-Link revision | 1.1.3 | ||||||||||||||
| SDCI standard | IEC 61131-9: 2013-07 | ||||||||||||||
| Profiles | Identification and Diagnosis (0x4000) | ||||||||||||||
| Required master port type | A | ||||||||||||||
| Process data analogue | 3 | ||||||||||||||
| Process data binary | 2 | ||||||||||||||
| Min. process cycle time [ms] | 9.6 | ||||||||||||||
| IO-Link process data (cyclical) |
|
||||||||||||||
| Supported DeviceIDs |
|
Operating conditions
| Ambient temperature [°C] | -20…60 |
|---|---|
| Storage temperature [°C] | -25…80 |
| Protection | IP 67 |
Tests / approvals
| EMC |
|
||
|---|---|---|---|
| Shock resistance |
|
||
| Vibration resistance |
|
||
| Pressure Equipment Directive | can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight [g] | 451.8 |
|---|---|
| Type of mounting | inlet pipe length 5xDN; outlet pipe length 1xDN |
| Materials | housing: stainless steel (1.4404 / 316L); Display: PFA; Sealing Display: FKM; connector: POKAN |
| Materials (wetted parts) | Pipe section: stainless steel (1.4404 / 316L); Process connection sealing: Centellen Flat seal |
| Process connection | G 1 DN25 external thread |
| Surface characteristics Ra/Rz of the wetted parts | 1.25 µm |
Displays / operating elements
| Display |
|
|---|
Accessories
| Items supplied |
|
|---|
Remarks
| Remarks |
|
||||
|---|---|---|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
|---|
Diagrams and graphs
|
Note on pressure loss
|
|
|---|
|
derating ambient temperature
|
|
|---|