Datasheet
Specification:
| Part Number | 1037979 |
| Storage temperature range: | -40 °C … 100 °C, without package |
| Reverse polarity protection: | 1 |
| Type of mounting shaft: | Solid shaft with flat |
| Connection type: | Cable, 8-wire, universal, 1.5 m |
| Shaft diameter: | 10 mm |
| Code type: | Gray |
| Resistance to vibration: | 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6) |
| Max. number of revolutions: | 1 |
| Working temperature range: | -30 °C … 100 °C |
| Power consumption: | 0.5 W (without load) |
| Maximum operating speed: | 9,000 /min |
| CW/CCW (counting sequence when turning): | L-active (L &;8801; 0 – 1,5 V, H &;8801; 2,0 – Us V) |
| MTTFd: mean time to dangerous failure: | 250 a (EN ISO 13849-1) |
| Resistance to shocks: | 60 g, 6 ms (according to EN 60068-2-27) |
| Operating voltage range: | 4.5 V DC … 32 V DC |
| Code sequence: | CW/CCW, parameter adjustable |
| Repeat accuracy: | 0.002 ° |
| Measuring step: | 0.014 ° 360 ° / number of steps |
| Error limits: | ± 0.03 ° |
| Bearing lifetime: | 3.0 x 10^9 revolutions |
| EMC: | (according to EN 61000-6-2 and EN 61000-6-3) |
| Permissible Load capacity of shaft: | 40 N (axial), 80 N (radial) |
| Moment of inertia of the rotor: | 6.2 gcm? |
| Permissible relative humidity: | 90 % (condensation of the optical scanning not permitted) |
| Measuring step deviation: | ± 0.002 ° |
| : | Face mount flange |
| Max. number of steps per revolution: | 65,536 |
| Initialization time: | 50 ms |
| Resolution power: | 65,536 x 1 |
| Mechanical interface: | Solid shaft with flat, Face mount flange |
| SET (electronic adjustment): | H-active (L &;8801; 0 – 1,5 V, H &;8801; 2,0 – Us V) |
| Enclosure rating: | IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side |
| Interface signals: | Clock +, Clock -, Data +, Data- |
| Max. angular acceleration: | 500,000 rad/s? |
| Clock frequency: | 2 MHz |
| Operating torque: | 0.3 Ncm (20 °C) |
| Start up torque: | 0.5 Ncm (20 °C) |
| Electrical interface: | SSI/Gray |