Home
» Sick » Sick ARS60-F1K32767

Sick ARS60-F1K32767

628.67

The price is not final. Please check with the manager!
SKU: ARS60-F1K32767 Categories: , , Brand:
  • Absolute singleturn encoder
  • Resolution: up to 15 bits (32,768 increments)
  • Electrical interface: SSI with gray code type or gray capped
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1031632
Resolution power: 32,767 x 1
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Operating torque: 0.2 Ncm
Permissible Load capacity of shaft: 10 N (axial), 20 N (radial)
Operation of zero-set: ≥ 100 ms
Error limits: 0.035 ° (binary number of steps)
0.046 ° (non-binary number of steps)
Max. number of revolutions: 1
Shaft diameter: 6 mm
Repeat accuracy: 0.005 °
Resistance to vibration: 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)
Operating voltage range: 10 V DC … 32 V DC
Electrical interface: Cable, 22-pin, radial, 1.5 m
Start up torque: 0.25 Ncm
Max. number of steps per revolution: 32,767
Mechanical interface: Solid shaft, Servo flange
Max. angular acceleration: 500,000 rad/s?
MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1)
Resistance to shocks: 50 g (according to EN 60068-2-27)
Initialization time: 80 ms
Working temperature range: -20 °C … 85 °C
Moment of inertia of the rotor: 48 gcm?
Storage temperature range: -40 °C … 100 °C
Bearing lifetime: 3.6 x 10^9 revolutions
Measuring step: 360 ° /number of lines
Maximum operating speed: 10,000 /min (without shaft seal), 6,000 /min (with shaft seal)
Operating power consumption (no load): 90 mA
Measuring step deviation: 0.005 °, 0.016 °
Enclosure rating: IP 66 (according to IEC 60529)
Permissible relative humidity: 90 % (condensation of the optical scanning not permitted)