Datasheet
Specification:
| Part Number | 1056287 |
| Single- and continuous shock: | EN 60068-2-27 |
| Medium: | Fluids |
| Max.probe load: | 6 Nm |
| Repeatability: | ≤ 2 mm |
| Accuracy of sensor element: | ± 5 mm |
| Signal voltage LOW: | ≤ 2 V |
| IO-Link: | + |
| UL approval: | + |
| Housing material: | 303 |
| EHEDG approval: | + |
| Lower signal level: | 3.8 mA … 4 mA |
| Power consumption: | ≤ 75 mA at 24 V DC without output load |
| Housing design: | With closed cover |
| Temperature drift: | < 0.1 mm/K |
| RoHS certificate: | + |
| 3-A: | – |
| Output load: | 0 V … 10 V > 750 Ohm at Uv >= 14 V, 4 mA … 20 mA < 400 Ohm at Uv > 12 V, 4 mA … 20 mA < 500 Ohm at Uv > 13,5 V |
| Conductivity: | No limitation |
| Response time: | < 400 ms |
| Process pressure: | -1 bar … 16 bar |
| GOST approval: | + |
| Capacitive load: | 100 nF |
| Connection type: | Round connector M12 x 1, 5-pin |
| Measurement: | Switch, Continuous |
| Protection class: | III |
| Process temperature: | -20 °C … +150 °C |
| Upper signal level: | 20 mA … 20.5 mA |
| Supply voltage: | 12 V DC … 30 V DC |
| MTTF: | 194.3 a (EN ISO 13849-1) |
| EMC: | EN 61326-1:2006, 2004/108/EG |
| Inactive area at probe end: | 10 mm |
| Ambient temperature operation: | -20 °C … +60 °C |
| Enclosure rating: | IP 67: EN 60529, IP 69K: EN 40050 |
| Ambient storage temperature: | -40 °C … +80 °C |
| Output current: | < 100 mA |
| Resolution: | < 2 mm |
| Inductive load: | < 1 H |
| Interference emission: | EN 61000-6-4:2007 |
| Inactive area at process connector: | 25 mm |
| Signal voltage HIGH: | Vs – 2 V |
| Hysteresis: | Min. 2 mm, free adjustable |
| Initialization time: | ≤ 2 s |
| Wetted parts: | 316L (Ra ≤ 0,8 µm), PEEK |
| Probe length: | 300 mm |
| Process connection: | G ? A |
| Dielectricity constant: | ≥ 1.8 with coaxial tube, ≥ 5 for mono probe |
| Interference resistance: | EN 61000-6-2:2005 |