SKU: LFP1500-G1NMB Categories: , , Brand:
  • Level monitoring in hygienic applications
  • Manually cutable monoprobe up to 4,000 mm long with Ra lessthan 0.8 µm
  • Process temperature up to 180 °C, process pressure up to 16 bar
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1052080
Ambient storage temperature: -40 °C … +80 °C
Max.probe load: 6 Nm
Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050
EMC: EN 61326-1:2006, 2004/108/EG
Resolution: < 2 mm
Process temperature: -20 °C … +150 °C
Inactive area at probe end: 10 mm
Capacitive load: 100 nF
Ambient temperature operation: -20 °C … +60 °C
Supply voltage: 12 V DC … 30 V DC
Conductivity: No limitation
Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe
Response time: < 400 ms
Repeatability: ≤ 2 mm
Connection type: Round connector M12 x 1, 5-pin
Housing material: 303
Hysteresis: Min. 2 mm, free adjustable
Probe length: 1,500 mm
Upper signal level: 20 mA … 20.5 mA
UL approval: +
Medium: Fluids
MTTF: 194.3 a (EN ISO 13849-1)
Interference resistance: EN 61000-6-2:2005
RoHS certificate: +
IO-Link: +
Lower signal level: 3.8 mA … 4 mA
Output current: < 100 mA
Power consumption: ≤ 75 mA at 24 V DC without output load
Measurement: Switch, Continuous
Inactive area at process connector: 25 mm
GOST approval: +
Process pressure: -1 bar … 16 bar
Initialization time: ≤ 2 s
Single- and continuous shock: EN 60068-2-27
Accuracy of sensor element: ± 5 mm
Interference emission: EN 61000-6-4:2007
Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK
Output load: 0 V … 10 V > 750 Ohm at Uv >= 14 V, 4 mA … 20 mA < 400 Ohm at Uv > 12 V, 4 mA … 20 mA < 500 Ohm at Uv > 13,5 V
Protection class: III
Process connection: G ¾ A
Housing design: With PMMA viewing window
Signal voltage LOW: ≤ 2 V
3-A:
Signal voltage HIGH: Vs – 2 V
Temperature drift: < 0.1 mm/K
EHEDG approval: +
Inductive load: < 1 H