SKU: CLV632-1831S01 Categories: , Brand:
  • Integrated pushbuttons for auto setup and reading diagnostics
  • Integrated LED bar graph
  • CAN, Ethernet TCP/IP, PROFINET, and EtherNet/IP available on board, no additional gateway needed (depending on variant)
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1062530
Function (CAN bus): SICK CAN sensor network (Master/Slave, Multiplexer/Server)
No. of characters per reading interval: 5,000, 500 (for multiplexer function in CAN operation)
No. of codes per reading interval: 1 … 50 (auto-discriminating)
Focus: Fixed focus
Print ratio: 2:1 … 3:1
DeviceNet: +
Ambient operating temperature: 0 °C … +40 °C
Protection class: III (EN 61140)
Remark (Serial (RS-232, RS-422/485)): AUX (only RS-232)
Field of view: ≤ 50 °
Remark (DeviceNet): Optional via external connection module (CDM + CMF)
Bar code print contrast (PCS): ≥ 60 %
Configuration software: SOPAS ET
MTBF: 40,000 h
Bar code types: Interleaved 2 of 5, All current code types, Codabar, Code 128, Code 39, Code 93, GS1 DataBar, GS1-128 / EAN 128, MSI/Plessey, Pharmacode, Telepen, UPC / GTIN / EAN
Housing color: Stainless steel (unpainted)
Electromagnetic compatibility (EMC): EN 61000-6-3 (2001-10) / EN 61000-6-2:2005
Function (Ethernet): Host, AUX
Front screen: Plastic
Operating voltage: 18 V DC … 30 V DC
Protocol (CAN bus): CANopen, CSN (SICK CAN Sensor Network)
Vibration resistance: EN 60068-2-6 (1995)
Permissible relative humidity: 90 %, non-condensing
CAN bus: +
Scanning frequency: 400 Hz … 1,200 Hz
Data transmission rate (Ethernet): 10/100 Mbit
Reading pulse: Auto pulse, CAN, Switching inputs, Serial interface
Light source: Visible red light (655 nm)
Switching inputs: 4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional CMC600 in CDB650)
Serial (RS-232, RS-422/485): +
Version: Short Range
Data transmission rate (CAN bus): 20 kbit/s … 1 Mbit/s
Enclosure rating: IP 69K (DIN 40 050, part 9)
Reading distance: 63 mm … 270 mm
PROFIBUS DP: +
Data transmission rate (Serial (RS-232, RS-422/485)): 2,400 Baud … 115 kBaud, AUX: 57.6 kBaud
Ambient light safety: 2,000 lx, on bar code
Laser class: 2 (EN 60825-1 (A2:2001-03))
Protocol (Ethernet): TCP/IP, EtherNet/IP, PROFINET, PROFINET Dual Port (optional via external connection module CDF600-2), EtherCAT (optional via external connection module CDF600)
No. of multiple readings: 1 … 99
Connection type: Ethernet
Switching outputs: 4 (“Result 1”, “Result 2”, 2 via CMC600 in CDB650)
No. of codes per scan: 1 … 20 (Standard decoder), 1 … 6 (SMART decoder)
Code resolution: 0.2 mm … 0.5 mm
Reading field: Front
Electrical connection: 2 x M12 cylindrical connectors (1 x 17-pin male connector, 4-pin female connector)
Scanner design: Raster scanner
Remark (PROFIBUS DP): Optional via external connection module (CDF600-2)
Power consumption: 5 W
Function (Serial (RS-232, RS-422/485)): Host, AUX
Weight: 890 g, without connecting cable
Shock resistance: EN 60068-2-27 (1993)
Ethernet: +
Housing: Stainless steel
Raster height, number of lines, at distance: 15 mm, 8, 200 mm
Dimensions: 85 mm x 154 mm x 84 mm
Storage temperature: -20 °C … +70 °C