Datasheet
Specification:
| Part Number | 1207876 |
| Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
| Housing material: | Aluminum alloy ALMGSI 0.5 |
| Type: | Type 2 (IEC 61496) |
| Resolution: | 14 mm |
| Test rate (internal test): | 47 /s |
| Connection type extension connection: | Female connector M12, 5-pin |
| Air humidity: | 15 % … 95 %, non-condensing |
| Protection class: | III (EN 61140) |
| Scanning range: | 0 m … 6 m |
| Storage temperature: | -25 °C … +70 °C |
| Switching voltage LOW: | 2 V DC |
| PFHd: | Cascaded systems: 5.2 1E-08 (EN ISO 13849) |
| Protective field height: | 720 mm |
| Switching voltage HIGH: | 24 V DC (VS – 2.25 V DC … VS) |
| Vibration resistance: | 5 g, 10 Hz … 55 Hz (EN 60068-2-6) |
| Performance level: | PL c (EN ISO 13849), Pay attention to optical characteristics! |
| Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
| Cable length: | 700 mm |
| Housing cross-section (incl. system connection): | 15 mm x 32 mm |
| Conductor cross-section: | 0.34 mm? |
| Power consumption: | ≤ 3 A |
| Typical range: | 0 m … 8 m |
| Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
| Restart interlock (delivery status): | Deactivated |
| Ambient operating temperature: | -20 °C … +55 °C |
| External device monitoring (delivery status): | Deactivated |
| Synchronization: | Optical, without separate synchronization |
| Restart interlock: | + |
| Connection type: | Male connector M12, 5-pin |
| Supply voltage: | 24 V DC (19.2 V DC … 28.8 V DC) |
| Response time: | ≤ 14 ms |
| Display elements: | LEDs |
| Enclosure rating: | IP 65 (EN 60529) |
| Permitted cable length: | ≤ 20 m |
| Category: | Category 2 (EN ISO 13849) |
| Configuration method: | Hard wired |
| Weight: | 255 g |
| Beam coding: | + |
| Switching current: | 300 mA |
| Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
| Maximum demand rate: | 28 /min (EN ISO 13849) |
| Safe SICK device communication via EFI/SDL: | – |
| Safety integrity level: | SIL1 (IEC 61508) SILCL1 (EN 62061) |
| TM (mission time): | 20 a (EN ISO 13849) |
| Ripple: | ≤ 10 % |
| Cascaded: | + |
| External device monitoring (EDM): | + |
| Automatic beam coding: | + |