Home
» Sick » Sick C4MT-06024ABB04FE0

Sick C4MT-06024ABB04FE0

0.00

The price is not final. Please check with the manager!
SKU: C4MT-06024ABB04FE0 Categories: , Brand:
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design – sender and receiver in a single housing
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1207289
Resolution: 24 mm
Cascaded: +
Type: Type 4 (IEC 61496)
Protection class: III (EN 61140)
Air humidity: 15 % … 95 %, non-condensing
Housing cross-section (incl. system connection): 15 mm x 32 mm
Category: Category 4 (EN ISO 13849)
Scanning range: 0 m … 4 m
Restart interlock (delivery status): Deactivated
Ripple: ≤ 10 %
Response time: ≤ 13 ms
Conductor cross-section: 0.34 mm?
Synchronization: Optical, without separate synchronization
Connection type: Male connector M12, 5-pin
Display elements: LEDs
External device monitoring (EDM): +
Safe SICK device communication via EFI/SDL:
Cable length: 700 mm
Connection type extension connection: Female connector M12, 5-pin
Restart interlock: +
Beam coding: +
Performance level: PL e (EN ISO 13849)
Shock resistance: 10 g, 16 ms (EN 60068-2-27)
Vibration resistance: 5 g, 10 Hz … 55 Hz (EN 60068-2-6)
Safety integrity level: SIL3 (IEC 61508)
SILCL3 (EN 62061)
Safe state in the event of a fault: At least one OSSD is in the OFF state.
PFHd: Cascaded systems: 1.3 1E-08 (EN ISO 13849)
Enclosure rating: IP 65 (EN 60529)
Storage temperature: -25 °C … +70 °C
Housing material: Aluminum alloy ALMGSI 0.5
Switching voltage LOW: 2 V DC
Power consumption: ≤ 3 A
Automatic beam coding: +
Supply voltage: 24 V DC (19.2 V DC … 28.8 V DC)
Switching current: 300 mA
Ambient operating temperature: -20 °C … +55 °C
Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored
Typical range: 0 m … 5 m
Protective field height: 600 mm
Switching voltage HIGH: 24 V DC (VS – 2.25 V DC … VS)
Permitted cable length: ≤ 20 m
TM (mission time): 20 a (EN ISO 13849)
Weight: 215 g
External device monitoring (delivery status): Deactivated
Configuration method: Hard wired
Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Sick C4MT-06024ABB04FE0