Schneider Electric High power contactor, TeSys Giga, 4 pole (4NO), AC-1 <=440V 700A, standard version, 100…250V wide band AC/DC coil

Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Main
Range TeSys
Range of product TeSys Giga
Product or component type Contactor
Device short name LC1G
Contactor application Power switching
Utilisation category AC-1
AC-5a
AC-5b
AC-6a
AC-6b
DC-1
DC-3
DC-5
Poles description 4P
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current 700 A (at <40 °C) at <= 1000 V AC-1
[Uc] control circuit voltage 100…250 V AC 50/60 Hz
100…250 V DC
Control circuit voltage limits Operational: 0.8 Uc Min…1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C)
Complementary
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 700 A (at 40 °C)
Rated breaking capacity 4600 A at 440 V
[Icw] rated short-time withstand current 4.0 kA – 10 s
2.8 kA – 30 s
2.2 kA – 1 min
1.5 kA – 3 min
1.2 kA – 10 min
Associated fuse rating 500 A aM at <= 440 V for motor
400 A aM at <= 690 V for motor
800 A gG at <= 690 V
Average impedance 0.00008 Ohm
[Ui] rated insulation voltage 1000 V
Power dissipation per pole 40 W AC-1 – Ith 700 A
Compatibility code LC1G
Pole contact composition 4 NO
Auxiliary contact composition 1 NO + 1 NC
Irms rated making capacity 5090 A at 440 V
Coil technology Built-in bidirectional peak limiting
Mechanical durability 5 Mcycles
8 Mcycles with sub-assembly substitution
inrush power in VA (50/60 Hz, AC) 750 VA
inrush power in W (DC) 660 W
hold-in power consumption in VA (50/60 Hz, AC) 15.5 VA
hold-in power consumption in W (DC) 9.3 W
Operating time 40…70 ms closing
15…50 ms opening
Maximum operating rate 300 cyc/h AC-1
Connections – terminals Power circuit: bar 2 – busbar cross section: 32 x 10 mm
Power circuit: lugs-ring terminals 1 185 mm²
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end
Connection pitch 45 mm
Mounting support Plate
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
Product certifications CB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque 35 N.m
Height 225 mm
Width 185 mm
Depth 226 mm
Net weight 8.2 kg
Environment
IP degree of protection IP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -60…80 °C
Mechanical robustness Vibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
Colour Dark grey
Protective treatment TH
Permissible ambient air temperature around the device -40…70 °C at Uc
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 28.0 cm
Package 1 Width 31.0 cm
Package 1 Length 31.5 cm
Package 1 Weight 9.675 kg
Unit Type of Package 2 S06
Number of Units in Package 2 4
Package 2 Height 75 cm
Package 2 Width 60 cm
Package 2 Length 80 cm
Package 2 Weight 48.7 kg