Datasheet
| Range of product | Lexium SD3 |
|---|---|
| Product or component type | Motion stepper drive |
| Device short name | SD328 |
| Supply voltage limits | 200…240 V 100…120 V |
| Bus type | Fieldbus |
| Format of the drive | Block |
|---|---|
| Network number of phases | Single phase |
| [Us] rated supply voltage | 100…120 V – 15…10 % 200…230 V – 15…10 % |
| Supply voltage type | AC/DC |
| Network frequency limits | 50…60 Hz (- 15…10 %) |
| Communication interface | Profibus DP fieldbus, integrated |
| Maximum motor phase current | 6.8 A |
| Current consumption | 5 A 230 V main supply 7 A 115 V main supply <= 0.2 mA 24 V control voltage |
| Nominal power | 280 W at 115 V 420 W at 230 V |
| Short-circuit current | 0.5 kA |
| Power losses | <= 65 W |
| Associated fuse rating | 10 A at 115 V 6 A at 230 V |
| Overvoltage category | III |
| Inrush current | 60 A |
| Maximum leakage current | 30 mA <10 m IEC 60990-3 |
| Voltage state 0 guaranteed | -3…5 V for 24 V input signals |
| Voltage state 1 guaranteed | 15…30 V for 24 V input signals |
| Input current | 10 mA for 24 V input signals |
| Maximum input frequency | 200 kHz for signal input ENC_A, ENC_B, ENC_I – control type pulse/direction 400 kHz for signal input ENC_A, ENC_B, ENC_I – control type A/B |
| Maximum output frequency | 400 kHz for pulse/direction interface A/B 200 kHz for pulse/direction interface pulse/direction |
| Maximum switching current | 50 mA (24 V output signals) |
| Maximum voltage drop | <1 V 50 mA load for 24 V output signals |
| Physical interface | RS422 – pulse/direction interface RS422 – signal input ENC_A, ENC_B, ENC_I |
| Output voltage | <= 30 V (24 V output signals) 4.75…5.25 V (ENC+5V_OUT signal output) |
| Input voltage | 24 V -15 %/+20 % for 24 V control voltage |
| Residual ripple | < 5 % (24 V control voltage) |
| Resistance | 5 kOhm (pulse/direction interface) |
| Safety function | Safe torque off safety function for machine conforming to IEC/EN 61800-5-2 Safe torque off safety function for machine conforming to ISO 13849-1 level d Safe torque off safety function for system process conforming to EN/IEC 61508 level SIL2 Safe torque off safety function for system process conforming to IEC/EN 61800-5-2 |
| Type of cooling | Fan |
| maximum mechanical speed | 3000 rpm |
| Height | 145 mm |
| Width | 72 mm |
| Depth | 140 mm |
| Shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
| Net weight | 1.2 kg |
| Electromagnetic compatibility | Electrostatic discharge level 3 conforming to EN/IEC 61000-4-2 Immunity to electrical transients level 4 conforming to EN/IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to EN/IEC 61000-4-3 Voltage/current impulse level 3 conforming to EN/IEC 61000-4-5 |
|---|---|
| Standards | EN/IEC 61800-3 environment 1 EN/IEC 61800-5-1 EN/IEC 61800-3 environment 2 EN/IEC 61800-3 EN/IEC 50178 |
| Product certifications | TÜV cUL UL |
| Marking | CE |
| Ambient air temperature for operation | 0…50 °C |
| Ambient air temperature for storage | -25…70 °C |
| Pollution degree | Level 2 |
| Relative humidity | 5…85 % without condensation |
| Operating altitude | <= 1000 m without derating > 1000…< 2000 m without derating (maximum ambient temperature 40°C, no protective film, lateral distance of > 50mm) |
| Vibration resistance | 1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 |
| IP degree of protection | IP20 On upper part: IP40 (without removal of protective film) |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 17 cm |
| Package 1 Width | 18 cm |
| Package 1 Length | 19.5 cm |
| Package 1 Weight | 1.34 kg |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30 cm |
| Package 2 Width | 40 cm |
| Package 2 Length | 60 cm |
| Package 2 Weight | 9.292 kg |
| Warranty | 18 months |
|---|