Datasheet
Variant | PRO | ||||
Application | Outdoor | ||||
Resolution power | High Resolution | ||||
Light source | Infrared (905 nm, ± 10 nm) | ||||
Laser class | 1 (EN/IEC 60825-1:2014 (Ed.3), EN/IEC 60825-1:2007 (Ed.2) CAN/CSA-E60825-1:2015-11 (Ed.3)) | ||||
|
|||||
Scanning frequency |
25 Hz 35 Hz 50 Hz 75 Hz 100 Hz |
||||
Angular resolution |
0.042°, interlaced 0.083°, interlaced 0.1667° 0.25° 0.333° 0.5° 0.667° 1° |
||||
Scan field flatness |
Scan field flatness combined: ± 0.72° Typical conical error: 1 sigma value – 0.11° ± 0.1° Typical tilt: 1 sigma value + 0.15° ± 0.08° |
||||
Heating | Self-heating with additional integrated heating | ||||
Working range | 0.2 m … 80 m | ||||
|
|||||
Measurement accuracy | ± 12 mm | ||||
Spot size |
Divergence: 4.7 mrad At the viewing window: 13.5 mm In 26 m: 136 mm In 40 m: 202 mm |
||||
Amount of evaluated echoes | 5 |