€0.00
The price is not final. Please check with the manager!
OPDLFPKG
- Inline quality control checks to ensure correct assembly of parts
- Quick set-up without software
- Universal use due to colour independence and insensitivity to extraneous light
-
Contact Sales
Datasheet
Electrical data
Operating voltage [V] |
10…30 DC; (“supply class 2” to cULus) |
Current consumption [mA] |
< 200 |
Current consumption reference voltage [V] |
10 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
2 |
Type of light |
red light |
Wave length [nm] |
650 |
Inputs / outputs
Number of inputs and outputs |
Number of digital inputs: 1; Number of digital outputs: 2 |
Inputs
Trigger |
external |
Number of digital inputs |
1 |
Outputs
Electrical design |
PNP/NPN; (parameterisable) |
Number of digital outputs |
2 |
Output function |
2 x normally open / normally closed; (parameterisable) |
Max. current load per output [mA] |
100 |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring/setting range
Measuring distance (Z-direction) [mm] |
150…300 |
Width of the measuring range (X-direction) at min. measuring distance [mm] |
45; (distance = 150mm) |
Width of the measuring range (X-direction) at max. measuring distance [mm] |
90; (distance = 300mm) |
Sampling rate [Hz] |
5 |
Accuracy / deviations
Measured value resolution |
Z-direction 200 µm |
X-direction 250 µm |
|
Accuracy |
Z-direction ± 500 µm |
X-direction ± 500 µm |
background white (90 % remission) |
|
Software / programming
Number of profiles which can be stored |
10 |
Number of regions of interest |
2 |
Interfaces
Communication interface |
IO-Link |
Transmission type |
COM3 (230,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Min. process cycle time [ms] |
2.3 |
IO-Link process data (cyclical) |
function |
bit length |
process value |
16 |
device status |
4 |
binary switching information |
1 |
|
IO-Link functions (acyclical) |
operating hours counter; number of trigger events; ROI setting |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
1260 |
|
Note |
For further information please see the IODD PDF file under “Downloads” |
|
Operating conditions
Ambient temperature [°C] |
-10…55 |
Storage temperature [°C] |
-40…60 |
Protection |
IP 65 |
Max. immunity to extraneous light [klx] |
20 |
Tests / approvals
EMC |
|
Laser protection class |
1 |
Notes on laser protection |
Caution: |
laser light |
laser class: |
1 |
|
EN / IEC60825-1:2007 |
|
EN / IEC60825-1:2014 |
|
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. |
|
MTTF [years] |
155 |
UL approval |
Ta |
-10…55 °C |
Enclosure type |
Type 1 |
power supply |
Class 2 |
File number UL |
E174191 |
|
Mechanical data
Weight [g] |
534.5 |
Dimensions [mm] |
88 x 65 x 28.5 |
Materials |
housing: diecast zinc; PPSU; ABS; PMMA; PBT / PC; EPDM; front pane: PMMA |
Displays / operating elements
Display |
switching status |
1 x LED, yellow |
Display operation |
1 x LED, green |
|
colour display |
|
Electrical connection
Connection |
Connector: 1 x M12; coding: A |
Diagrams and graphs
|
1
|
X-direction |
2
|
Z-direction |
3
|
laser beam aperture |
4
|
receiver |
|
Other data
light line
measuring distance (Z-direction) |
light line |
150 mm |
50 x 1 mm |
300 mm |
100 x 1 mm |
The values apply at |
|
Extraneous light on the object |
< 20 klx |
constant ambient conditions |
23 °C / 960 hPa |
minimum power-on time in minutes |
10 |