Specification:
Part Number | 1061997 |
Initialization time: | < 3 ms |
Measuring step deviation: | ± 18 ° / impulses per relovution |
Operating speed: | 6,000 /min |
Shaft material: | Stainless steel |
Mechanical interface: | Solid shaft, Face mount flange |
Load current max.: | 30 mA |
Electrical interface: | 7 V … 30 V, HTL/Push pull |
Resistance to shocks: | 100 g (EN 60068-2-27) |
Permissible shaft loading radial/axial: | 20 N (axial), 40 N (radial) |
Error limits: | ± 54 ° (/pulses per revolution) |
Flange material: | Aluminum |
Reference signal, position: | 90 °, electronically, gated with A and B |
Connection type: | Cable, 8-wire, universal, 0.5 m |
Reference signal, number: | 1 |
Housing material: | Aluminum |
Duty cycle: | ≤ 0.5 ± 5 % |
Bearing lifetime: | 2 x 10^9 revolutions |
Power consumption max. without load: | Without load |
Max. angular acceleration: | 500,000 rad/s? |
Operating torque: | 0.4 Ncm (+20 °C) |
Storage temperature range: | -40 °C … +100 °C, without package |
Permissible relative humidity: | 90 % (condensation of the optical scanning not permitted) |
Operating voltage range: | 7 V … 30 V |
Start up torque: | 0.5 Ncm (+20 °C) |
EMC: | (according to EN 61000-6-2 and EN 61000-6-4 (class A)) |
MTTFd: mean time to dangerous failure: | 600 a (EN ISO 13849-1) |
Working temperature range: | -20 °C … +85 °C |
Maximum operating speed: | 8,000 U/min |
Material, cable: | PVC |
Pulses per revolution: | 200 |
Enclosure rating: | IP 65 |
Measuring step: | 90 ° / electronically/pulses |
Operating power consumption (no load): | 50 mA |
Resistance to vibration: | 20 g, 10 Hz … 2,000 Hz (EN 60068-2-6) |
Shaft diameter: | 6 mm x 12 mm |
Maximum output frequency: | 300 kHz |
Moment of inertia of the rotor: | 0.6 gcm? |
Reverse polarity protection: | 1 |
Short-circuit protection of the outputs: | 1 |