Datasheet
Product characteristics
| Output function | normally closed |
|---|---|
| Sensing range [mm] | 35 |
| Housing | rectangular |
Application
| Special feature | Increased sensing range |
|---|
Electrical data
| Operating voltage [V] | 20…250 AC/DC |
|---|---|
| Protection class | I |
| Reverse polarity protection | no |
Outputs
| Output function | normally closed |
|---|---|
| Max. voltage drop switching output DC [V] | 6 |
| Max. voltage drop switching output AC [V] | 6.5 |
| Minimum load current [mA] | 1.9 |
| Max. leakage current [mA] | 2.5 (250 V AC) / 1.3 (130 V AC) / 0.8 (24 V DC) |
| Permanent current rating of switching output AC [mA] | 250; (350 (…50 °C)) |
| Permanent current rating of switching output DC [mA] | 100 |
| Short-time current rating of switching output [mA] | 2200; (20 ms / 0,5 Hz) |
| Switching frequency AC [Hz] | 20 |
| Switching frequency DC [Hz] | 50 |
| Short-circuit proof | no |
| Overload protection | no |
Detection zone
| Sensing range [mm] | 35 |
|---|---|
| Operating distance [mm] | 0…28.3 |
| Increased sensing range | yes |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 |
|---|---|
| Hysteresis [% of Sr] | 3…15 |
Operating conditions
| Ambient temperature [°C] | -25…70 |
|---|---|
| Protection | IP 67 |
Tests / approvals
| EMC |
|
||||
|---|---|---|---|---|---|
| MTTF [years] | 600 |
Mechanical data
| Weight [g] | 164 |
|---|---|
| Housing | rectangular |
| Mounting | non-flush mountable |
| Materials | housing: PPE; sensing face: PPE orange; end cap: PPS; clamp: PPS black; screw: steel galvanised |
Displays / operating elements
| Display |
|
|---|
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
|---|
Remarks
| Remarks |
|
||
|---|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection – plug
| Connector: 1 x 1/2″; coding: C; Locking: brass, white bronze coated |