Product characteristics
| Resolution | 50 resolution |
|---|---|
| Shaft design | solid shaft |
| Shaft diameter [mm] | 6 |
Application
| Function principle | incremental |
|---|
Electrical data
| Operating voltage [V] | 10…30 DC |
|---|---|
| Current consumption [mA] | < 150 |
Outputs
| Electrical design | HTL |
|---|---|
| Max. current load per output [mA] | 50 |
| Switching frequency [kHz] | 300 |
| Type of short-circuit protection | < 60 s |
| Phase difference A and B [°] | 90 |
Measuring/setting range
| Resolution | 50 resolution |
|---|
Operating conditions
| Ambient temperature [°C] | -40…100 | |
|---|---|---|
| Note on ambient temperature |
|
|
| Max. relative air humidity [%] | 98 | |
| Protection | IP 64; (on the housing: IP 67; on the shaft: IP 64) |
Tests / approvals
| Shock resistance |
|
||
|---|---|---|---|
| Vibration resistance |
|
Mechanical data
| Weight [g] | 479.3 | |
|---|---|---|
| Dimensions [mm] | Ø 58 / L = 44.6 | |
| Materials | aluminium | |
| Max. revolution, mechanical [U/min] | 16000 | |
| Max. starting torque [Nm] | 1 | |
| Reference temperature torque [°C] | 20 | |
| Shaft design | solid shaft | |
| Shaft diameter [mm] | 6 | |
| Shaft material |
|
|
| Max. shaft load axial (at the shaft end) [N] | 10 | |
| Max. shaft load radial (at the shaft end) [N] | 20 |
Electrical connection
| Cable: 2 m, PUR; Maximum cable length: 300 m; radial, can also be used axially |
Diagrams and graphs
|
Pulse diagram
|
|
|---|