Home
» IFM Electronic » IFM SA4300 Flow sensor

IFM SA4300 Flow sensor

296.86

The price is not final. Please check with the manager!
SKU: SA4300 Categories: , , Brand:

SAEXXXXBFRKG/US-100

  • Measurement of flow and temperature at the same time
  • Optimised for water, oils and air
  • Red/green display for clear identification of the acceptable range
  • With swit
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Process connection diameter Ø 8 mm
Application
Special feature Gold-plated contacts
Media water; glycol solutions; air; oils
Note on media
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)
high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature [°C] -20…100
Pressure rating [bar] 50
Pressure rating [Mpa] 5
MAWP (for applications according to CRN) [bar] 50
Electrical data
Operating voltage [V] 18…30 DC
Current consumption [mA] < 100
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 10
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; frequency signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 250
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 350
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Frequency of the output [Hz] 0…1000
Measuring/setting range
Probe length L [mm] 200
Operating mode relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended)
Note on factory setting
Operating mode: relative
Temperature monitoring
Measuring range [°C] -20…100
Resolution [°C] 0.2
Liquid media – absolute operating mode
Setting range [m/s] 0.04…3
Greatest sensitivity [m/s] 0.04…3
Liquid media – relative operating mode
Setting range [m/s] 0.04…6
Greatest sensitivity [m/s] 0.04…3
Gases – operating mode "absolute"
Setting range [m/s] 0…100
Greatest sensitivity [m/s] 30…100
Gases – operating mode "relative"
Setting range [m/s] 0…200
Greatest sensitivity [m/s] 30…100
Accuracy / deviations
Temperature drift [cm/s x 1/K] 0,003 m/s x 1/K (< 20 °C; > 70 °C)
Temperature gradient [K/min] 100
Absolute operating mode
Repeatability 0,05 m/s; (water; flow velocity: 0,05…3 m/s)
Relative operating mode
Accuracy ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20…70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)
Repeatability 0,05 m/s; (water; flow velocity: 0,05…3 m/s)
Temperature monitoring
Temperature drift ± 0,005 K/°C
Accuracy [K] ± 0,3 / ± 1; (water; flow velocity: 0,3…3 m/s / air; flow velocity: > 10 m/s)
Response times
Response time [s] 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)
Temperature monitoring
Dynamic response T05 / T09 [s] 1,5 (T09); (water; flow velocity: 0,3…3 m/s)
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 2
Min. process cycle time [ms] 3
Supported DeviceIDs
Type of operation DeviceID
Factory setting / ModE = (REL) 533
ModE = (LIQU) 540
ModE = (GAS) 547
Operating conditions
Ambient temperature [°C] -40…80
Storage temperature [°C] -40…100
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 60947-5-9
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 2 g (10…2000 Hz)
MTTF [years] 180
UL approval
UL Approval no. I017
File number UL E174189
Mechanical data
Weight [g] 345.5
Materials stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30
Materials (wetted parts) stainless steel (1.4404 / 316L)
Process connection diameter Ø 8 mm
Displays / operating elements
Display
Display unit 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
switching status 2 x LED, yellow
measured values alphanumeric display, red/green 4-digit
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews