€342.93
The price is not final. Please check with the manager!
O1DLF3KG/IO-LINK
- Reliable optical distance measurement with high ranges up to 10 m
- Two switching outputs, one of them programmable as analogue output
- Scalable measuring range and window funct
Contact Sales
Returns
14 days return. New condition only.
Shipping
EU, USA, worldwide.
DHL, DPD, UPS.
O1DLF3KG/IO-LINK
- Reliable optical distance measurement with high ranges up to 10 m
- Two switching outputs, one of them programmable as analogue output
- Scalable measuring range and window funct
Datasheet
Product characteristics
| Laser protection class |
2 |
| Housing |
rectangular |
Electrical data
| Operating voltage [V] |
18…30 DC; (“supply class 2” to cULus) |
| Current consumption [mA] |
< 150 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Typ. lifetime [h] |
50000 |
Inputs / outputs
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
| Total number of outputs |
2 |
| Electrical design |
PNP |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. current load per output [mA] |
200 |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20; (IEC 61131-2) |
| Max. load [Ω] |
250 |
| Analogue voltage output [V] |
0…10; (IEC 61131-2) |
| Min. load resistance [Ω] |
5000 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
Detection zone
| Max. light spot width [mm] |
15 |
| Max. light spot height [mm] |
15 |
| Light spot dimensions refer to |
10 m |
| Background suppression [m] |
0…19 |
Measuring/setting range
| Measuring range [m] |
0.2…10; (white paper 200 x 200 mm 90% remission) |
| Sampling rate [Hz] |
1…50 |
Interfaces
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
2 |
| Process data binary |
3 |
| Min. process cycle time [ms] |
6 |
| Supported DeviceIDs |
|
Type of operation |
DeviceID |
|
Default |
1548 |
|
Operating conditions
| Ambient temperature [°C] |
-10…60 |
| Protection |
IP 67 |
Tests / approvals
| EMC |
|
| Laser protection class |
2 |
| Notes on laser protection |
|
Caution: |
laser light |
|
Power: |
<= 4 mW |
|
Wave length: |
650 nm |
|
pulse: |
1,3 ns |
|
Do not stare into beam. |
|
|
Avoid exposure to the laser light. |
|
|
laser class: |
2 |
|
|
EN / IEC60825-1:2007 |
|
|
EN / IEC60825-1:2014 |
|
|
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. |
|
| UL approval |
|
Ta |
-10…60 °C |
|
Enclosure type |
Type 1 |
|
power supply |
Class 2 |
|
File number UL |
E174191 |
|
Mechanical data
| Weight [g] |
248.8 |
| Housing |
rectangular |
| Dimensions [mm] |
59 x 42 x 52 |
| Materials |
housing: diecast zinc; front pane: glass; LED window: PC |
| Lens alignment |
side lens |
Displays / operating elements
| Display |
|
switching status |
2 x LED, yellow |
|
operation |
LED, green |
|
distance value, programming |
alphanumeric display, 4-digit |
|
Remarks
| Remarks |
|
For more information about the measuring range / application please refer to the operating instructions. |
|
| Pack quantity |
1 pcs. |
Electrical connection
| Connection |
Connector: 1 x M12; coding: A |
Other data
| Parameter |
Setting range |
Factory setting |
| Uni |
mm, m |
mm |
| OU1 |
Hno, Hnc, Fno, Fnc |
Hno |
| SP1 [mm] |
200…9999 |
1000 |
| nSP1 [mm] |
200…9999 |
800 |
| FSP1 [mm] |
200…9999 |
1200 |
| OU2 |
Hno, Hnc, Fno, Fnc, I, U |
I |
| SP2 [mm] |
200…9999 |
2000 |
| nSP2 [mm] |
200…9999 |
1800 |
| FSP2 [mm] |
200…9999 |
2200 |
| ASP [mm] |
0…9999 |
0 |
| AEP [mm] |
0…9999 |
9999 |
| rATE [Hz] |
1…50 |
50 |
| dS1 [s] |
0…0.1…5 |
0 |
| dr1 [s] |
0…0.1…5 |
0 |
| dS2 [s] |
0…0.1…5 |
0 |
| dr2 [s] |
0…0.1…5 |
0 |
| dFo [s] |
0…0.1…5 |
0 |
| dIS |
d1…3 ; rd1…3; OFF |
d3 |
repeatability/accuracy
| read/write distance (mm) |
repeatability of the measured values |
|
accuracy |
|
|
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
| 200…1000 mm |
± 5.0 mm |
±7.5 mm |
± 15.0 mm |
± 18.0 mm |
| 1000…2000 mm |
± 5.5 mm |
±10.0 mm |
± 15.0 mm |
± 20.0 mm |
| 2000…4000 mm |
± 17.5 mm |
±22.5 mm |
± 25.0 mm |
± 32.0 mm |
| 4000…6000 mm |
± 27.5 mm |
±40.0 mm |
± 35.0 mm |
± 50.0 mm |
| 6000…10000 mm |
± 60.0 mm |
|
± 70.0mm |
|
| Sampling rate |
50 Hz |
| Extraneous light on the object |
< 40 klx |
repeatability/accuracy
| read/write distance (mm) |
repeatability of the measured values |
|
accuracy |
|
|
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
| 200…1000 mm |
± 16.5 mm |
±16.5 mm |
± 26.5 mm |
± 26.5 mm |
| 1000…2000 mm |
± 16.5 mm |
±16.5 mm |
± 26.5 mm |
± 26.5 mm |
| 2000…4000 mm |
± 30.0 mm |
±37.0 mm |
± 40.0 mm |
± 47.0 mm |
| 4000…6000 mm |
± 37.0 mm |
±57.0 mm |
± 47.0 mm |
± 67.0 mm |
| 6000…10000 mm |
± 75.0 mm |
— |
± 85.0mm |
— |
| Sampling rate |
50 Hz |
| Extraneous light on the object |
40…100 klx |
repeatability/accuracy
| read/write distance (mm) |
repeatability of the measured values |
|
accuracy |
|
|
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
| 200…1000 mm |
± 4.0 mm |
±4.5 mm |
± 14.0 mm |
± 15.0 mm |
| 1000…2000 mm |
± 4.5 mm |
±6.0 mm |
± 14.5 mm |
± 16.0 mm |
| 2000…4000 mm |
± 13.5 mm |
±14.5 mm |
± 23.5 mm |
± 24.0 mm |
| 4000…6000 mm |
± 19.0 mm |
±21.0 mm |
± 29.0 mm |
± 31.0 mm |
| 6000…10000 mm |
± 37.0 mm |
– |
± 47.0mm |
– |
| Sampling rate |
1 Hz |
| Extraneous light on the object |
< 40 klx |
repeatability/accuracy
| read/write distance (mm) |
repeatability of the measured values |
|
accuracy |
|
|
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
| 200…1000 mm |
± 10.0 mm |
± 10.0 mm |
± 20.0 mm |
± 20.0 mm |
| 1000…2000 mm |
± 10.0 mm |
± 10.0 mm |
± 20.0 mm |
± 20.0 mm |
| 2000…4000 mm |
± 17.0 mm |
± 18.0 mm |
± 27.0 mm |
± 28.0 mm |
| 4000…6000 mm |
± 22.0 mm |
± 25.0 mm |
± 32.0 mm |
± 35.0 mm |
| 6000…10000 mm |
± 37.0 mm |
– |
± 47.0mm |
– |
| Sampling rate |
1 Hz |
| Extraneous light on the object |
< 40…100 klx |
| Range on black object (6 % remission) |
<= 4000 mm |
| The values apply at |
|
| Extraneous light on the object |
< 100 klx |
| constant ambient conditions |
23 °C / 960 hPa |
| minimum power-on time in minutes |