Home
» IFM Electronic » IFM OGD582 Photoelectric distance sensor

IFM OGD582 Photoelectric distance sensor

0.00

The price is not final. Please check with the manager!
SKU: OGD582 Categories: , , Brand:

OGDLFPKG/IO-LINK/US

  • Simultaneous output of distance value and reflectivity for increased process reliability
  • Identification and sorting by differentiating between colour/contrast and distance/height
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Product characteristics
Type of light red light
Laser protection class 1
Housing rectangular with M18 thread
Electrical data
Operating voltage [V] 10…30 DC; (“supply class 2” to cULus)
Current consumption [mA] < 75
Current consumption reference voltage [V] 24
Protection class III
Reverse polarity protection yes
Type of light red light
Wave length [nm] 650
Typ. lifetime [h] 50000
Inputs
Inputs Laser On/ Off
Outputs
Electrical design PNP
Output function 2 x normally open / normally closed; (parameterisable)
Max. current load per output [mA] 100
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Max. light spot diameter [mm] 5
Light spot dimensions refer to at maximum range
Background suppression [m] < 20
Measuring/setting range
Measuring range [m] 0.085…1.5
Setting range object reflectivity [%] 6…900; (reflectivity; 6 % black paper; 100 % white paper)
Sampling rate [Hz] 33
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Min. process cycle time [ms] 5
IO-Link process data (cyclical)
function bit length
process value 2 x 16
device status 4
binary switching information 2
IO-Link functions (acyclical) application specific tag; operating hours counter; switching cycles counter
Supported DeviceIDs
Type of operation DeviceID
Default 926
Note
For further information please see the IODD PDF file under “Downloads”
Operating conditions
Ambient temperature [°C] -25…60
Note on ambient temperature
In ambient temperatures < -10 °C a warm-up time is necessary.
Laser is off.
Storage temperature [°C] -30…80
Protection IP 65; IP 67
Tests / approvals
Laser protection class 1
Notes on laser protection
Caution: laser light
laser class: 1
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 217
UL approval
Ta -25…60 °C
Enclosure type Type 1
power supply Class 2
File number UL E174191
Mechanical data
Weight [g] 229.8
Housing rectangular with M18 thread
Dimensions [mm] 61.7 x 22.5 x 45.2
Thread designation M18 x 1
Materials housing: stainless steel (1.4404 / 316L); PPSU; ABS; PMMA; PBT / PC; EPDM; front pane: glass
Lens alignment side lens
Displays / operating elements
Display
switching status 2 x LED, yellow
1 x alphanumeric display, 3-digit
Operating elements
3 pushbutton
Accessories
Items supplied
lock nuts: 2
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Diagrams and graphs

a: sensor
b: object
c: background
x: distance sensor/object [mm]
y: min. distance object/background [mm]
hysteresis curve for distance measurement

x: distance sensor/object [mm]
y: min. distance object/background [mm]
1 = background (black 6 % remission)
2 = $Hintergrund_weiss_90_Remission

1: bright
2: dark
A: switch point
B: reset point
x: object brightness ( object reflectivity )
y: min. reflectivity difference to be detected safely
hysteresis curve for object reflectivity

x: object reflectivity ( 0..900 % )
y: Hysteresis [%]
1 = optional hysteresis curve ( high )
2 = Hysteresis Factory setting ( low )
Other data
Parameter Setting range Factory setting
Uni cm cm
OU1 Hno, Hnc, Fno, Fnc, OFF Hno
SP1 [cm] 8.5…150 150
nP1 [cm] 8.5…150 20
FP1 [cm] 8.5…150 25
LG1 And,Or,Off Off
dS1 [s] 0…0.1…5 0
dr1 [s] 0…0.1…5 0
OU2 Hno, Hnc, Fno, Fnc, OFF Hno
SP2 [%] 6…900 6
bP2 [%] 6…900 60
dP2 [%] 6…900 30
HyL Lo/Hi Lo
LG2 And,Or,Off Off
dS2 [s] 0…0.1…5 0
dr2 [s] 0…0.1…5 0
dFO [s] 0…0.1…5 0.1
dIS ON / OFF ON
Repeatability: 6 σ
repeatability of the measured values
distance white (90 % remission) black (6 %…90 % remission)
85 mm 8.0 mm 15.0 mm
750 mm 8.0 mm 15.0 mm
1500 mm 20.0 mm 60.0 mm
The values apply at
Extraneous light on the object < 10 klx
constant ambient conditions 23 °C / 960 hPa
minimum power-on time in minutes 15