Datasheet
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 | |||
|---|---|---|---|---|
| Measuring range |
|
|||
| Process connection | threaded connection G 1/4 external thread internal thread:M5 |
Application
| Application | for industrial applications | |||
|---|---|---|---|---|
| Media | liquids and gases | |||
| Medium temperature [°C] | -25…90 | |||
| Min. bursting pressure |
|
|||
| Pressure rating |
|
|||
| Type of pressure | relative pressure |
Electrical data
| Operating voltage [V] | 9.6…36 DC; (communication mode: 18…32) |
|---|---|
| Current consumption [mA] | < 45 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 0.3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250 |
| Switching frequency DC [Hz] | 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range |
|
|||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Set point SP |
|
|||||||||
| Reset point rP |
|
|||||||||
| In steps of |
|
|||||||||
| Factory setting |
|
Accuracy / deviations
| Switch point accuracy [% of the span] | < ± 0,5 |
|---|---|
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span] | < ± 0,1 |
| Long-term stability [% of the span] | < ± 0,1; (per year) |
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0…80 °C) |
| Temperature coefficient span [% of the span / 10 K] | 0,2; (0…80 °C) |
Response times
| Response time [ms] | < 3 |
|---|---|
| Damping process value dAP in steps [s] | 0,003 – 0,006 – 0,010 – 0,017 – 0,060 – 0,125 – 0,250 – 0,500 |
Operating conditions
| Ambient temperature [°C] | -25…85 |
|---|---|
| Storage temperature [°C] | -40…100 |
| Protection | IP 69K; IP 68; (7 days / 1 m water depth / 0.1 bar) |
Tests / approvals
| EMC |
|
||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Shock resistance |
|
||||||||||||||||||
| Vibration resistance |
|
||||||||||||||||||
| MTTF [years] | 308 | ||||||||||||||||||
| UL approval |
|
||||||||||||||||||
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight [g] | 211.1 |
|---|---|
| Materials | stainless steel (1.4301 / 304); FKM; EPDM/X; PA |
| Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1/4 external thread internal thread:M5 |
| Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements
| Display |
|
||||
|---|---|---|---|---|---|
| Teach function | yes |
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connection | Connector: 1 x M12; coding: A |
|---|