Main
Range of productSepam series 20
Device short nameS10UD
user machine interface typeAdvanced
Complementary
UMI indicationMetering and diagnosis data
Status of logic imputs
Alarms and operating messages
Protection setting
Sepam parameter setting
Version of Sepam and remote modules
UMI controlAlarm acknowledgement
Output testing
Sepam reset
Display resolution128 x 64 pixels
Number of key9
Local signalling2 LEDs for Sepam operating status (front face)
9 LEDs for indication of parameters (front face)
Output typeAnnunciation relay: 100…240 V AC 47.5…63 Hz continuous current: 2 A breaking capacity: 1 A cos φ > 0.3
Annunciation relay: 127 V DC continuous current: 2 A breaking capacity: 0.5 A L/R < 20 ms
Annunciation relay: 220 V DC continuous current: 2 A breaking capacity: 0.15 A L/R < 20 ms
Annunciation relay: 24 V DC continuous current: 2 A breaking capacity: 2 A L/R < 20 ms
Annunciation relay: 48 V DC continuous current: 2 A breaking capacity: 1 A L/R < 20 ms
Control relay: 100…240 V AC 47.5…63 Hz continuous current: 8 A breaking capacity: 5 A cos φ > 0.3 making capacity: < 15 A for 200 ms
Control relay: 100…240 V AC 47.5…63 Hz continuous current: 8 A breaking capacity: 8 A resistive making capacity: < 15 A for 200 ms
Control relay: 127 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 40 ms making capacity: < 15 A for 200 ms
Control relay: 127 V DC continuous current: 8 A breaking capacity: 0.5 A L/R < 20 ms making capacity: < 15 A for 200 ms
Control relay: 127 V DC continuous current: 8 A breaking capacity: 0.7 A resistive making capacity: < 15 A for 200 ms
Control relay: 220 V DC continuous current: 8 A breaking capacity: 0.1 A L/R < 40 ms making capacity: < 15 A for 200 ms
Control relay: 220 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 20 ms making capacity: < 15 A for 200 ms
Control relay: 220 V DC continuous current: 8 A breaking capacity: 0.3 A resistive making capacity: < 15 A for 200 ms
Control relay: 24 V DC continuous current: 8 A breaking capacity: 4 A L/R < 40 ms making capacity: < 15 A for 200 ms
Control relay: 24 V DC continuous current: 8 A breaking capacity: 6 A L/R < 20 ms making capacity: < 15 A for 200 ms
Control relay: 24 V DC continuous current: 8 A breaking capacity: 8 A resistive making capacity: < 15 A for 200 ms
Control relay: 48 V DC continuous current: 8 A breaking capacity: 1 A L/R < 40 ms making capacity: < 15 A for 200 ms
Control relay: 48 V DC continuous current: 8 A breaking capacity: 2 A L/R < 20 ms making capacity: < 15 A for 200 ms
Control relay: 48 V DC continuous current: 8 A breaking capacity: 4 A resistive making capacity: < 15 A for 200 ms
[Us] rated supply voltage110/240 V AC 47.5…63 Hz tolerance: – 20…10 % deactivated consumption: < 6 VA maximum consumption: < 15 VA
24/250 V DC tolerance: – 20…10 % deactivated consumption: < 4.5 W maximum consumption: < 8 W
Supply inrush current< 10 A for 10 ms at 24/250 V DC
< 15 A at 110/240 V AC
Mounting modeFixed
Mounting supportPlate
Height222 mm
Width176 mm
Depth129 mm
Net weight1.42 kg
Power frequency dielectric withstand2 kV during 1 min conforming to IEC 60255-5
[Uimp] rated impulse withstand voltage5 kV (1.2/50 µs) conforming to IEC 60255-5
Mechanical robustnessEarthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
Shocks de-energized (level: 2) : 30 Gn/11 ms conforming to IEC 60255-21-2
Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
Vibrations de-energized (level: 2) : 2 Gn, 10 Hz…150 Hz conforming to IEC 60255-21-1
Vibrations in operation (level: 2) : 1 Gn, 10 Hz…150 Hz conforming to IEC 60255-21-1
Vibrations in operation (level: Fc) : 2 Hz…13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
Environment
StandardsEN 50263
CSA C22.2 No 0.17-00
CSA C22.2 No 94-M91
CSA C22.2 No 14-95
UL 508
Product certificationsCE
UL 508 file N° 212533
C22.2 file N° 210625
Fire resistance650 °C conforming to IEC 60695-2-11
IP degree of protectionOther panels: IP20 conforming to IEC 60529
Front panel: IP52 conforming to IEC 60529
NEMA degree of protectionType 12 conforming to NEMA
Immunity to microbreaks10 ms
Electromagnetic compatibility1 MHz damped oscillating wave: (immunity tests-conducted disturbances), III, 2.5 kV MC, 1 kV MD, conforming to IEC 60255-22-1
Fast transient bursts: (immunity tests-conducted disturbances), A or B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4
Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4
Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8
Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz…2 GHz, conforming to IEC 61000-4-3
Surges: (immunity tests-conducted disturbances), III, 2 kV MC, 1 kV MD, conforming to IEC 61000-4-5
1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC and MD, conforming to ANSI C37.90.1
100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC, 1 kV MD, conforming to IEC 61000-4-12
Conducted disturbance emission: (emission tests), conforming to IEC 60255-25
Conducted disturbance emission: (emission tests), B, conforming to EN 55022
Disturbing field emission: (emission tests), conforming to IEC 60255-25
Disturbing field emission: (emission tests), A, conforming to EN 55022
Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3
Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2
Fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1
Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), 10 V, conforming to IEC 60255-22-6
Immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz…1 GHz, conforming to IEC 60255-22-3
Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz…1 GHz, conforming to ANSI C37.90.2 (1995)
Voltage interruptions: (immunity tests-conducted disturbances), 100 %, 10 ms, conforming to IEC 60255-11
Climatic withstandContinuous exposure to damp heat (in operation) : Ca: 10 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3
Continuous exposure to damp heat (in storage) : Ca: 56 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3
Exposure to cold (in operation) : Ab: – 25 °C (- 13 °F) conforming to IEC 60068-2-1
Exposure to cold (in storage) : Ab: – 25 °C (- 13 °F) conforming to IEC 60068-2-1
Exposure to dry heat (in operation) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2
Exposure to dry heat (in storage) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2
Influence of corrosion/gaz test 2 (in operation) : C: 21 days, 75 % RH, 25 °C (- 13 °F), 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60
Temperature variation with specified variation rate (in operation) : Nb: – 25 °C to 70 °C (- 13 °F to 158 °F) 5 °C/min (41 °F/min) conforming to IEC 60068-2-14
Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.02 ppm NO2, 0.01 ppm Cl2 conforming to IEC 60068-2-60
Salt mist (in operation) : Kb/2 conforming to IEC 60068-2-52
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height12.200 cm
Package 1 Width27.200 cm
Package 1 Length26.700 cm
Package 1 Weight1.206 kg
Unit Type of Package 2S03
Number of Units in Package 23
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight4.105 kg
Unit Type of Package 3P12
Number of Units in Package 324
Package 3 Height50.000 cm
Package 3 Width80.000 cm
Package 3 Length120.000 cm
Package 3 Weight44.840 kg