Schneider LV848260

0.00

The price is not final. Please check with the manager!

Schneider Electric Circuit breaker frame, MasterPact MTZ2 12H2, 1250A, 100kA/440VAC 50/60Hz (Icu), 3P, drawout, without control unit

Ask a Question

Datasheet

Main
RangeMasterPacT
Product nameMasterPact MTZ2
Device short nameMTZ2 12 H2
Product or component typeCircuit breaker
Device applicationPower distribution protection
Poles description3P
Control unitWithout control unit
[In] rated current1250 A at 40 °C
Performance typeH2 100 kA 440 V AC
[Ue] rated operational voltage690 V AC 50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Selectivity categoryCategory B
Control typePush-button
Mounting modeDrawout
Complementary
[Icu] rated ultimate short-circuit breaking capacity100 kA at 220/415 V AC 50/60 Hz
100 kA at 440 V AC 50/60 Hz
85 kA at 500/525 V AC 50/60 Hz
85 kA at 660/690 V AC 50/60 Hz
[Ics] rated service breaking capacity100 kA at 220/415 V AC 50/60 Hz
100 kA at 440 V AC 50/60 Hz
85 kA at 500/525 V AC 50/60 Hz
85 kA at 660/690 V AC 50/60 Hz
[Icw] rated short-time withstand current85 kA 0.5 s
85 kA 1 s
50 kA 3 s
[Icm] rated short-circuit making capacity220 kA 220/415 V AC at 50/60 Hz
220 kA 440 V AC at 50/60 Hz
187 kA 500/525 V AC at 50/60 Hz
187 kA 660/690 V AC at 50/60 Hz
Integrated instantaneous protection (DIN in kA peak)171…209 kA
Sensor rating630 A
800 A
1000 A
1250 A
[Ui] rated insulation voltage1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage12 kV
Power dissipation in W230 W
Maximum breaking time25 ms
Maximum closing response time70 ms
Mounting supportRails
Base plate
upside connectionFront
Rear
Downside connectionFront
Rear
Connection pitch115 mm
Mechanical durability25000 cycles with periodic preventive maintenance
Electrical durability10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
AC-23A: 10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-23A: 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3
HeightDrawout circuit breaker with chassis: 439 mm
Drawout circuit breaker without chassis: 300 mm
WidthDrawout circuit breaker with chassis: 441 mm
Drawout circuit breaker without chassis: 378 mm
DepthDrawout circuit breaker with chassis: 403 mm
Drawout circuit breaker without chassis: 300 mm
Net weight90 kg
StandardsEN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
IEC 61557-12
Product certificationsCE
IECEE CB Scheme
Environment
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Operating altitude0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height29.5 cm
Package 1 Width30.5 cm
Package 1 Length37.5 cm
Package 1 Weight47.036 kg