Schneider LV848280

0.00

The price is not final. Please check with the manager!

Schneider Electric Circuit breaker frame, MasterPact MTZ2 16H1, 1600A, 66kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit

Ask a Question

Datasheet

Main
RangeMasterPacT
Product nameMasterPact MTZ2
Device short nameMTZ2 16 H1
Product or component typeCircuit breaker
Device applicationPower distribution protection
Poles description4P
Neutral positionLeft
Control unitWithout control unit
[In] rated current1600 A at 40 °C
Performance typeH1 66 kA 440 V AC
[Ue] rated operational voltage690 V AC 50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Selectivity categoryCategory B
Control typePush-button
Mounting modeDrawout
Complementary
[Icu] rated ultimate short-circuit breaking capacity66 kA at 220/415 V AC 50/60 Hz
66 kA at 440 V AC 50/60 Hz
66 kA at 500/525 V AC 50/60 Hz
66 kA at 660/690 V AC 50/60 Hz
[Ics] rated service breaking capacity66 kA at 220/415 V AC 50/60 Hz
66 kA at 440 V AC 50/60 Hz
66 kA at 500/525 V AC 50/60 Hz
66 kA at 660/690 V AC 50/60 Hz
[Icw] rated short-time withstand current66 kA 0.5 s
66 kA 1 s
36 kA 3 s
[Icm] rated short-circuit making capacity145 kA 220/415 V AC at 50/60 Hz
145 kA 440 V AC at 50/60 Hz
145 kA 500/525 V AC at 50/60 Hz
145 kA 660/690 V AC at 50/60 Hz
Sensor rating800 A
1000 A
1250 A
1600 A
[Ui] rated insulation voltage1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage12 kV
Power dissipation in W390 W
Maximum breaking time25 ms
Maximum closing response time70 ms
Mounting supportRails
Base plate
upside connectionFront
Rear
Downside connectionFront
Rear
Connection pitch115 mm
Mechanical durability25000 cycles with periodic preventive maintenance
Electrical durability10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
AC-23A: 10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-23A: 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3
HeightDrawout circuit breaker with chassis: 439 mm
Drawout circuit breaker without chassis: 300 mm
WidthDrawout circuit breaker with chassis: 556 mm
Drawout circuit breaker without chassis: 493 mm
DepthDrawout circuit breaker with chassis: 403 mm
Drawout circuit breaker without chassis: 300 mm
Net weight120 kg
StandardsEN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
IEC 61557-12
Product certificationsCE
IECEE CB Scheme
Environment
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Operating altitude0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height30.5 cm
Package 1 Width29.5 cm
Package 1 Length49.5 cm
Package 1 Weight47.653 kg

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider LV848280