Schneider Electric Circuit breaker frame, MasterPact MTZ2 16H2, 1600A, 100kA/440VAC 50/60Hz (Icu), 3P, drawout, without control unit

Contact Sales

Datasheet

Main
Range MasterPacT
Product name MasterPact MTZ2
Device short name MTZ2 16 H2
Product or component type Circuit breaker
Device application Power distribution protection
Poles description 3P
Control unit Without control unit
[In] rated current 1600 A at 40 °C
Performance type H2 100 kA 440 V AC
[Ue] rated operational voltage 690 V AC 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Selectivity category Category B
Control type Push-button
Mounting mode Drawout
Complementary
[Icu] rated ultimate short-circuit breaking capacity 100 kA at 220/415 V AC 50/60 Hz
100 kA at 440 V AC 50/60 Hz
85 kA at 500/525 V AC 50/60 Hz
85 kA at 660/690 V AC 50/60 Hz
[Ics] rated service breaking capacity 100 kA at 220/415 V AC 50/60 Hz
100 kA at 440 V AC 50/60 Hz
85 kA at 500/525 V AC 50/60 Hz
85 kA at 660/690 V AC 50/60 Hz
[Icw] rated short-time withstand current 85 kA 0.5 s
85 kA 1 s
50 kA 3 s
[Icm] rated short-circuit making capacity 220 kA 220/415 V AC at 50/60 Hz
220 kA 440 V AC at 50/60 Hz
187 kA 500/525 V AC at 50/60 Hz
187 kA 660/690 V AC at 50/60 Hz
Integrated instantaneous protection (DIN in kA peak) 171…209 kA
Sensor rating 800 A
1000 A
1250 A
1600 A
[Ui] rated insulation voltage 1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 12 kV
Power dissipation in W 390 W
Maximum breaking time 25 ms
Maximum closing response time 70 ms
Mounting support Rails
Base plate
upside connection Front
Rear
Downside connection Front
Rear
Connection pitch 115 mm
Mechanical durability 25000 cycles with periodic preventive maintenance
Electrical durability 10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
AC-23A: 10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-23A: 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3
Height Drawout circuit breaker with chassis: 439 mm
Drawout circuit breaker without chassis: 300 mm
Width Drawout circuit breaker with chassis: 441 mm
Drawout circuit breaker without chassis: 378 mm
Depth Drawout circuit breaker with chassis: 403 mm
Drawout circuit breaker without chassis: 300 mm
Net weight 90 kg
Standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
IEC 61557-12
Product certifications CE
IECEE CB Scheme
Environment
IP degree of protection IP30 conforming to EN 60529
Pollution degree 3 conforming to IEC 60947-1
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Operating altitude 0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 30.5 cm
Package 1 Width 29.5 cm
Package 1 Length 37.5 cm
Package 1 Weight 47.035 kg