Schneider LV848317

0.00

The price is not final. Please check with the manager!

Schneider Electric Circuit breaker frame, MasterPact MTZ2 32H1, 3200A, 66kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit

Contact Sales

Datasheet

Main
Range MasterPacT
Product name MasterPact MTZ2
Device short name MTZ2 32 H1
Product or component type Circuit breaker
Device application Power distribution protection
Poles description 4P
Neutral position Left
Control unit Without control unit
[In] rated current 3200 A at 40 °C
Performance type H1 66 kA 440 V AC
[Ue] rated operational voltage 690 V AC 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Selectivity category Category B
Control type Push-button
Mounting mode Drawout
Complementary
[Icu] rated ultimate short-circuit breaking capacity 66 kA at 220/415 V AC 50/60 Hz
66 kA at 440 V AC 50/60 Hz
66 kA at 500/525 V AC 50/60 Hz
66 kA at 660/690 V AC 50/60 Hz
[Ics] rated service breaking capacity 66 kA at 220/415 V AC 50/60 Hz
66 kA at 440 V AC 50/60 Hz
66 kA at 500/525 V AC 50/60 Hz
66 kA at 660/690 V AC 50/60 Hz
[Icw] rated short-time withstand current 66 kA 0.5 s
66 kA 1 s
66 kA 3 s
[Icm] rated short-circuit making capacity 145 kA 220/415 V AC at 50/60 Hz
145 kA 440 V AC at 50/60 Hz
145 kA 500/525 V AC at 50/60 Hz
145 kA 660/690 V AC at 50/60 Hz
Sensor rating 1600 A
2000 A
2500 A
3200 A
[Ui] rated insulation voltage 1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 12 kV
Power dissipation in W 670 W
Maximum breaking time 25 ms
Maximum closing response time 70 ms
Mounting support Rails
Base plate
upside connection Front
Rear
Downside connection Front
Rear
Connection pitch 115 mm
Mechanical durability 20000 cycles with periodic preventive maintenance
Electrical durability AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3
2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
AC-23A: 2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-23A: 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Height Drawout circuit breaker with chassis: 439 mm
Drawout circuit breaker without chassis: 300 mm
Width Drawout circuit breaker with chassis: 556 mm
Drawout circuit breaker without chassis: 493 mm
Depth Drawout circuit breaker with chassis: 403 mm
Drawout circuit breaker without chassis: 300 mm
Net weight 120 kg
Standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
IEC 61557-12
Product certifications CE
IECEE CB Scheme
Environment
IP degree of protection IP30 conforming to EN 60529
Pollution degree 3 conforming to IEC 60947-1
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Operating altitude 0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 30.5 cm
Package 1 Width 29.5 cm
Package 1 Length 49.5 cm
Package 1 Weight 53.254 kg