Schneider LV848335

0.00

The price is not final. Please check with the manager!

Schneider Electric Circuit breaker frame, MasterPact MTZ3 63H1, 6300A, 100kA/440VAC (Icu), 4P, drawout right Neutral, without control unit

Contact Sales

Datasheet

Main
Range MasterPacT
Product name MasterPact MTZ3
Device short name MTZ3 63 H1
Product or component type Circuit breaker
Device application Power distribution protection
Poles description 4P
Neutral position Right
Control unit Without control unit
[In] rated current 6300 A at 40 °C
Performance type H1 100 kA 440 V AC
[Ue] rated operational voltage 690 V AC 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Selectivity category Category B
Control type Push-button
Mounting mode Drawout
Complementary
[Icu] rated ultimate short-circuit breaking capacity 100 kA at 220/415 V AC 50/60 Hz
100 kA at 440 V AC 50/60 Hz
100 kA at 500/525 V AC 50/60 Hz
100 kA at 660/690 V AC 50/60 Hz
[Ics] rated service breaking capacity 100 kA at 220/415 V AC 50/60 Hz
100 kA at 440 V AC 50/60 Hz
100 kA at 500/525 V AC 50/60 Hz
100 kA at 660/690 V AC 50/60 Hz
[Icw] rated short-time withstand current 100 kA 0.5 s
100 kA 1 s
100 kA 3 s
[Icm] rated short-circuit making capacity 220 kA 220/415 V AC at 50/60 Hz
220 kA 440 V AC at 50/60 Hz
220 kA 500/525 V AC at 50/60 Hz
220 kA 660/690 V AC at 50/60 Hz
Sensor rating 3200 A
4000 A
5000 A
6300 A
[Ui] rated insulation voltage 1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 12 kV
Power dissipation in W 900 W
Maximum breaking time 25 ms
Maximum closing response time 80 ms
Mounting support Rails
Base plate
upside connection Rear
Downside connection Rear
Connection pitch 230 mm
Mechanical durability 10000 cycles with periodic preventive maintenance
Electrical durability AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3
1500 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
1500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
AC-23A: 1500 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
AC-23A: 1500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3
Height Drawout circuit breaker with chassis: 479 mm
Drawout circuit breaker without chassis: 300 mm
Width Drawout circuit breaker with chassis: 1016 mm
Drawout circuit breaker without chassis: 838 mm
Depth Drawout circuit breaker with chassis: 403 mm
Drawout circuit breaker without chassis: 300 mm
Net weight 300 kg
Standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 60947-2 Annex H
IEC 61557-12
Product certifications CE
IECEE CB Scheme
Environment
IP degree of protection IP30 conforming to EN 60529
Pollution degree 3 conforming to IEC 60947-1
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Operating altitude 0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 60.0 cm
Package 1 Width 120.0 cm
Package 1 Length 50.0 cm
Package 1 Weight 133.324 kg

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider LV848335