Schneider LC1F1700

0.00

The price is not final. Please check with the manager!

Schneider Electric contactor, TeSys F, 3P(3NO), AC-1, <=1000V AC 1700A with coil LX1/LX9, 110…500V AC 40/400Hz, LX4, 110...440V DC

Ask a Question

Datasheet

Main
RangeTeSys
Product nameTeSys F
Product or component typeContactor
Device short nameLC1F
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current1700 A (at <40 °C) at <= 440 V AC AC-1
Complementary
[Uc] control circuit voltage110…500 V AC 40…400 Hz with LX1/LX9 coil
110…440 V DC with LX4 coil
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current1700 A (at 40 °C)
Irms rated making capacity2550 A AC conforming to IEC 60947-4-1
Rated breaking capacity2550 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current10000 A 40 °C – 10 s for power circuit
7500 A 40 °C – 30 s
5500 A 40 °C – 1 min
4200 A 40 °C – 3 min
3000 A 40 °C – 10 min
Associated fuse rating1600 A gG at <= 440 V for power circuit conforming to IEC 60947-4-1
Average impedance0.1 mOhm – Ith 1700 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
1000 V conforming to UL 60947-4-1
Power dissipation per pole200 W AC-1
Control circuit voltage limitsOperational: 0.85…1.1 Uc AC 40…400 Hz with LX1/LX9 coil
Drop-out: 0.3…0.5 Uc AC 40…400 Hz with LX1/LX9 coil
Operational: 0.85…1.1 Uc DC with LX4 coil
Drop-out: 0.2…0.35 Uc DC with LX4 coil
Heat dissipation18 W
Operating time40…75 ms closing for with LX1/LX9 coil
100…170 ms opening for with LX1/LX9 coil
50…60 ms closing for with LX4 coil
45…60 ms opening for with LX4 coil
Mounting supportPlate
StandardsEN 60947-1
JIS C8201-4-1
IEC 60947-1
EN 60947-4-1
IEC 60947-4-1
UL 60947-4-1A
CSA C22.2 No 60947-4-1
Product certificationsCB Scheme
CCC
CSA
UL
EAC
UKCA
Connections – terminalsPower circuit: bar 3 cable(s) – busbar cross section: 100 x 5 mm
Power circuit: bolted connection
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Tightening torquePower circuit: 58 N.m
Control circuit: 1.2 N.m
Mechanical durability0.5 Mcycles
Inrush power in VA1600…2400 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
2000…2200 VA (at 20 °C)with LX4 coil
Hold-in power consumption in VA29…37 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
8…10 VA (at 20 °C)with LX4 coil
Maximum operating rate600 cyc/h 55 °C
Environment
Protective treatmentTH
Ambient air temperature for operation-5…40 °C
Ambient air temperature for storage-60…80 °C
Permissible ambient air temperature around the device-40…60 °C
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5…300 Hz
Vibrations contactor closed: 4 Gn, 5…300 Hz
Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Height332 mm
Width438 mm
Depth238.6 mm
Net weight30 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height39.5 cm
Package 1 Width50.0 cm
Package 1 Length62.0 cm
Package 1 Weight30.0 kg
Contractual warranty
Warranty18 months

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider LC1F1700