Schneider LC1F1250

0.00

The price is not final. Please check with the manager!

Schneider Electric contactor, TeSys F, 3P(3NO), AC-1 <=440V 1260A with coil LX1/ LX9, 110…600V AC 40/400Hz, LX4, 48…250V DC

Contact Sales

Datasheet

Main
Range TeSys
Product name TeSys F
Product or component type Contactor
Device short name LC1F
Contactor application Resistive load
Utilisation category AC-1
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage <= 690 V AC 50/60 Hz
[Ie] rated operational current 1260 A (at <40 °C) at <= 440 V AC-1
Complementary
[Uc] control circuit voltage 110…600 V AC 40…400 Hz with LX1/LX9 coil
28…250 V DC with LX4 coil
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 1260 A (at 40 °C)
Irms rated making capacity 1890 A conforming to IEC 60947-4-1
Rated breaking capacity 1890 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 3000 A 40 °C – 3 min
5200 A 40 °C – 30 s
4000 A 40 °C – 1 min
2000 A 40 °C – 10 min
8000 A 40 °C – 10 s
Associated fuse rating 1400 A gG at <= 440 V for power circuit
Average impedance 0.12 mOhm – Ith 1260 A 50 Hz
[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole 120 W AC-1
Control circuit voltage limits Operational: 0.85…1.1 Uc AC 40…400 Hz with LX1/LX9 coil
Drop-out: 0.25…0.5 Uc AC 40…400 Hz with LX1/LX9 coil
Operational: 0.85…1.1 Uc DC with LX4 coil
Drop-out: 0.2…0.35 Uc DC with LX4 coil
Heat dissipation 20 W
Operating time 40…80 ms closing for with LX1/LX9 coil
100…200 ms opening for with LX1/LX9 coil
60…70 ms closing for with LX4 coil
40…50 ms opening for with LX4 coil
Mounting support Plate
Standards IEC 60947-1
EN 60947-1
JIS C8201-4-1
EN 60947-4-1
IEC 60947-4-1
Product certifications CB
cETLus
CSA
CCC
UKCA
Connections – terminals Power circuit: bar 2 cable(s)
Power circuit: bolted connection
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Tightening torque Power circuit: 58 N.m
Control circuit: 1.2 N.m
Mechanical durability 1 Mcycles
Inrush power in VA 1500…1730 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
1420…1920 VA (at 20 °C)with LX4 coil
Hold-in power consumption in VA 20…25 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
6.5…12.5 VA (at 20 °C)with LX4 coil
Maximum operating rate 1200 cyc/h 55 °C
Environment
Protective treatment TH
Ambient air temperature for operation -5…40 °C
Ambient air temperature for storage -60…80 °C
Permissible ambient air temperature around the device -40…60 °C
Operating altitude 3000 m without derating
Mechanical robustness Vibrations contactor open: 2 Gn, 5…300 Hz
Vibrations contactor closed: 4 Gn, 5…300 Hz
Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Height 338 mm
Width 309 mm
Depth 255 mm
Net weight 19 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 33.0 cm
Package 1 Width 37.0 cm
Package 1 Length 44.0 cm
Package 1 Weight 20.1 kg
Contractual warranty
Warranty 18 months