Home
» Schneider Electric » Variable Speed Drives » Altivar 71 » Schneider ATV71ES5C50N4

Schneider ATV71ES5C50N4

0.00

The price is not final. Please check with the manager!

Schneider Electric enclosed variable speed drive ATV71 Plus – 500 kW – 400V – IP54 – ready to use

Contact Sales

Datasheet

Main
Range of product Altivar 71 Plus
Product or component type Variable speed drive
Device short name ATV71 Plus
Product destination Synchronous motors
Asynchronous motors
Product specific application Complex, high-power machines
Assembly style In floor-standing enclosure with separate air flows
Ready to use
product composition Circuit breaker
Motor terminals
A wired ready-assembled Sarel Spacial 6000 enclosure
ATV71HC50N4 drive on heatsink
A plinth
An IP65 remote mounting kit for graphic display terminal
A DC choke
EMC filter Integrated
Network number of phases 3 phases
rated supply voltage 380…415 V +/- 10 %
Supply voltage limits 342…457 V
Supply frequency 50…60 Hz +/- 5 %
Network frequency 47.5…63 Hz
Motor power kW 500 kW at 380…415 V
Line current 834 A for 400 V / 500 kW
Complementary
Apparent power 577 kVA for 400 V / 500 kW
Prospective line Isc 50 kA with external fuses
Continuous output current 941 A at 2.5 kHz, 400 V / 500 kW
Maximum transient current 1412 A for 60 s / 500 kW / 700 hp
1553 A for 2 s / 500 kW / 700 hp
Speed drive output frequency 0.1…500 Hz
Nominal switching frequency 2.5 kHz
Switching frequency 2…8 kHz adjustable
2.5…8 kHz with derating factor
Speed range 1…1000 for asynchronous motor in closed-loop mode with encoder feedback
1…100 for asynchronous motor in open-loop mode, without speed feedback
1…50 for synchronous motor in open-loop mode, without speed feedback
Speed accuracy +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn
+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Torque accuracy +/- 5 % in closed-loop mode with encoder feedback
+/- 15 % in open-loop mode, without speed feedback
Transient overtorque 170 % of nominal motor torque +/- 10 % for 60 s
220 % of nominal motor torque +/- 10 % for 2 s
Braking torque 30 % without braking resistor
<= 150 % with braking or hoist resistor
Asynchronous motor control profile Flux vector control without sensor, ENA (energy Adaptation) system
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 5 points
Flux vector control without sensor, 2 points
Flux vector control with sensor, standard
Flux vector control without sensor, standard
Voltage/frequency ratio, 2 points
Synchronous motor control profile Vector control with sensor, standard
Vector control without sensor, standard
Regulation loop Adjustable PI regulator
Motor slip compensation Suppressable
Not available in voltage/frequency ratio (2 or 5 points)
Adjustable
Automatic whatever the load
Overvoltage category Class 3 conforming to EN 50178
Local signalling LCD display unit for operation function, status and configuration
Output voltage <= supply voltage
Isolation Electrical between power and control
type of cable for external connection IEC cable at 40 °C, copper 70 °C / PVC
UL 508 cable at 40 °C, copper 75 °C / PVC
Electrical connection Terminal – 2.5 mm² / AWG 14 (R1A, R1B, R1C, R2A, R2B) bottom entry
Screw clamp terminals – 1.5 mm² (AI1-/AI1+, AI2, AO1, LI1…LI6, PWR) bottom entry
Bar M12 – 6 x 300 mm² (L1/R, L2/S, L3/T) bottom entry
Bar M12 – 6 x 240 mm² (U/T1, V/T2, W/T3) bottom entry
Motor recommanded cable cross section 4 (3 x 185) mm²
Short-circuit protection 1250 A fuse protection type gI – power supply upstream
Supply External supply: 24 V DC (19…30 V), <1 A
Internal supply for reference potentiometer: 10 V DC (10…11 V), <10 mA
Internal supply: 24 V DC (21…27 V), <100 mA
Analogue input number 2
Analogue input type AI2 software-configurable voltage: 0…10 V DC, 24 V max, impedance: 30000 Ohm, sampling time: 1.5…2.5 ms, resolution: 11 bits
AI1-/Al1+ bipolar differential voltage: +/- 10 V DC, 24 V max, sampling time: 1.5…2.5 ms, resolution: 11 bits + sign
AI2 software-configurable current: 0…20 mA/4…20 mA, impedance: 250 Ohm, sampling time: 1.5…2.5 ms, resolution: 11 bits
Analogue output number 1
Analogue output type Software-configurable voltage: (AO1) 0…10 V DC – 470 Ohm – sampling time: 1.5…2.5 ms – resolution: 10 bits
Software-configurable current: (AO1) 0…20 mA/4…20 mA – 500 Ohm – sampling time: 1.5…2.5 ms – resolution: 10 bits
Discrete output number 2
Discrete output type Configurable relay logic: (R1A, R1B, R1C)NO/NC – 6.5…7.5 ms – 100000 cycles
Configurable relay logic: (R2A, R2B)NO – 6.5…7.5 ms – 100000 cycles
Minimum switching current 3 mA at 24 V DC (configurable relay logic)
Maximum switching current 5 A at 250 V AC on resistive load – cos phi = 1 (R1, R2)
5 A at 30 V DC on resistive load – L/R = 0 ms (R1, R2)
2 A at 250 V AC on inductive load – cos phi = 0.4 (R1, R2)
2 A at 30 V DC on inductive load – L/R = 7 ms (R1, R2)
Discrete input number 7
Discrete input type Programmable (LI1…LI5) at 24 V DC <= 30 V level 1 PLC 3.5 kOhm (duration=1.5…2.5 ms)
Switch-configurable (LI6) at 24 V DC <= 30 V level 1 PLC 1.5 kOhm (duration=1.5…2.5 ms)
Safety input (PWR) at 24 V DC <= 30 V 1.5 kOhm
Discrete input logic Positive logic (source) (LI1…LI6), 0…5 V (state 0), 11…30 V (state 1)
Negative logic (sink) (LI1…LI6), 16…30 V (state 0), 0…10 V (state 1)
Positive logic (source) (PWR), 0…2 V (state 0), 17…30 V (state 1)
Acceleration and deceleration ramps S, U or customized
Linear adjustable separately from 0.01 to 9000 s
Braking to standstill By DC injection
Protection type Overheating protection: drive
Thermal protection: drive
Short-circuit between motor phases: drive
Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overvoltages on the DC bus: drive
Break on the control circuit: drive
Against exceeding limit speed: drive
Line supply undervoltage: drive
Line supply overvoltage: drive
Against input phase loss: drive
Thermal protection: motor
Motor phase break: motor
Power removal: motor
Dielectric strength 3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Insulation resistance > 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution Display unit: 0.1 Hz
Analog input: 0.024/50 Hz
communication port protocol CANopen
Modbus
Connector type 1 RJ45 (on front face) for Modbus
1 RJ45 (on terminal) for Modbus
Male SUB-D 9 on RJ45 for CANopen
Physical interface 2-wire RS 485 for Modbus
Transmission frame RTU for Modbus
Transmission rate 9600 bps, 19200 bps for Modbus on front face
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
Data format 8 bits, 1 stop, even parity for Modbus on front face
8 bits, odd even or no configurable parity for Modbus on terminal
Type of polarization No impedance for Modbus
Number of addresses 1…247 for Modbus
1…127 for CANopen
Method of access Slave CANopen
Operating position Vertical +/- 10 degree
Colour of enclosure Light grey (RAL 7035)
Colour of base of enclosure Dark grey (RAL 7022)
Height 2362 mm
Width 1600 mm
Depth 642 mm
Net weight 900 kg
Environment
Electromagnetic compatibility Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Pollution degree 2 conforming to EN/IEC 61800-5-1
IP degree of protection IP54
Vibration resistance 1.5 mm peak to peak (f= 3…10 Hz) conforming to EN/IEC 60068-2-6
0.6 gn (f= 10…200 Hz) conforming to EN/IEC 60068-2-6
3M3 conforming to EN/IEC 60721-3-3
Shock resistance 4 gn for 11 ms conforming to EN/IEC 60068-2-27
3M2 conforming to EN/IEC 60721-3-3
Noise level 73 dB conforming to 86/188/EEC
Environmental characteristic Without condensation: 3C2 conforming to IEC 60721-3-3
Without condensation: 3S2 conforming to IEC 60721-3-3
Without condensation: 3K3 conforming to IEC 60721-3-3
Relative humidity 0…95 %
Ambient air temperature for operation 0…40 °C (without derating)
40…50 °C (with current derating of 1.2 % per °C)
Ambient air temperature for storage -25…70 °C
Volume of cooling air 3000 m3/h
Operating altitude <= 1000 m without derating
1000…3000 m with current derating 1 % per 100 m
Standards EN 61800-3 environments 2 category C3
EN/IEC 61800-5-1
EN/IEC 61800-3
EN 61800-3 environments 1 category C3
EN 55011 class A group 2
Product certifications ATEX
GOST
Marking CE
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 240.0 cm
Package 1 Width 62.0 cm
Package 1 Length 162.0 cm
Package 1 Weight 900.0 kg
Unit Type of Package 2 CAR
Number of Units in Package 2 1
Package 2 Height 260.0 cm
Package 2 Width 90.0 cm
Package 2 Length 180.0 cm
Package 2 Weight 900.0 kg
Contractual warranty
Warranty 18 months

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider ATV71ES5C50N4