Schneider Electric MicroLogic 7.0Xi control unit, no wireless, MasterPact MTZ2, drawout circuit breakers, LSIV protections

Contact Sales

Datasheet

Main
Range MasterPacT
Device short name MicroLogic 7.0 Xi
Product or component type Control unit
Device application Equipment protection, monitoring and control
Circuit breaker application Distribution IEC standard
Range compatibility MasterPact MTZ2 circuit breaker
Poles 3P
4P
Protected poles description 3P 3d
4P 3d
4P 3d + N/2
4P 4d
4P 3d + OSN
[Ue] rated operational voltage 600 V AC, +/- 10 %
Network type AC
Network frequency 50/60 Hz
Trip unit technology Electronic
Trip unit protection functions LSIV
Protection type Overload protection (long time) conforming to ANSI 49
Instantaneous short-circuit protection conforming to ANSI 50
Short time short-circuit protection conforming to ANSI 51
Earth-leakage protection conforming to ANSI 51G
Trip unit rating 800 A
1000 A
1250 A
1600 A
2000 A
2500 A
3200 A
Complementary
Control type Wired control
Mounting mode Drawout
Neutral protection setting 1 x Ir (4P 4d)
0.5 x Ir (4P 3d + N/2)
1.6 x Ir (4P 3d + OSN)
No protection (4P 3d)
[Ir] long time pick-up adjustment range 0.4…1 x In adjustable in step of 1 A
long time delay adjustment type Adjustable in step of 0.5 s
[tr] long-time delay adjustment range 12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.7…16.6 s at 7.2 x Ir
Thermal memory Yes
[Isd] short-time pick-up adjustment range 1.5…10 x Ir adjustable in step of 0.5 x Ir with embedded HMI
1.5…10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app
Short-time delay adjustment type Adjustable
[tsd] short-time delay adjustment range 0.1…0.4 s I²t=on
0…0.4 s I²t=off
Instantaneous pick-up adjustment type Ii Adjustable
[Ii] instantaneous pick-up adjustment range 2…15 x In adjustable in step of 0.5 x In with embedded HMI
2…15 x In adjustable in step of 0.1 x In with Ecoreach software or MasterPact MTZ mobile app
Ii enable on/off
[li mode] instantaneous delay adjustment range 0 ms in fast
20 ms in standard
Earth-leakage protection With
[IΔn] residual earth-leakage sensitive adjustment 0.5…30 A adjustable in step of 0.1 A
Residual earth-leakage time delay adjustment type Adjustable
[Δt] residual earth-leakage time delay adjustment 60…800 ms resettable time
140…1000 ms break time
Zone selective interlocking ZSI With
Network and machine diagnosis type System (HMI) health state overview: circuit breaker health state
Contacts state: circuit breaker health state
MicroLogic service life: circuit breaker health state
Tripping cause indication: circuit breaker tripping cause
Identification card: diagnostic data
Configured alarms synthesis: diagnostic data
Monitored function: diagnostic data
Operation: diagnostic data
MicroLogic test: test
Protection test: test
Selectivity test: test
Trip context information: crisis management
Operation: advanced diagnostic
Breaker service life: circuit breaker health state
type of measurement Power meter
Energy management Measurement ,active, reactive and apparent energy
Measurement ,electrical network
Measurement ,energy
Metering type Current I1, I2, I3, Iavg RMS
Neutral current IN RMS
Ground fault current Ig RMS
Voltage V12, V23, V31, VLLavg RMS
Voltage V1N, V2N, V3N, VLNavg RMS
Active power P, P1, P2, P3 total
Reactive power Q, Q1, Q2, Q3 total
Apparent power S, S1, S2, S3 total
Power factor
Active energy Ep IN/OUT/tot
Reactive energy Eq IN/OUT/tot
Apparent energy Es IN/OUT/tot
Demand current I1, I2, I3, In, Iavg
Demand power P, Q, S
Frequency
Phase sequence
Earth leakage current
Total current harmonic distortion THD (I)
Total voltage harmonic distortion THD (V)
Unbalance current
Unbalance voltage
Measurement voltage 208…828 V AC 50/60 Hz phase to phase
120…480 V AC 50/60 Hz phase to neutral
Frequency measurement range 40…70 Hz
Measurement accuracy Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40…1600 x 1.2 A
Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40…4000 x 1.2 A
Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80…6300 x 1.2 A
Neutral current IN: +/- 1 %
Ground fault current Ig: +/- 5 %
Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208…690 x 1.2 V
Voltage V1N, V2N, V3N, VLNavg: +/- 0.5 % 120…400 x 1.2 V
Active power P, P1, P2, P3, Pdemand: +/- 1 %
Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 %
Apparent power S, S1, S2, S3, Sdemand: +/- 1 %
Power factor: +/- 2 %
Active energy Ep IN/OUT/tot: +/- 1 %
Reactive energy Ep IN/OUT/tot: +/- 2 %
Apparent energy Es IN/OUT/tot: +/- 1 %
Frequency: +/- 0.005 Hz
Earth leakage current: +/- 10 %
Unbalance current: +/- 0.5 %
Accuracy class Class 5: total current harmonic distortion THD (I)
Class 0.5: unbalance voltage
Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h)
Class 2: total voltage harmonic distortion THD (V)
Display type LCD display – 128 x 96 pixels
Communication port protocol USB peer to peer 115 kbauds
NFC peer to peer 28800 bauds conforming to ISO 15963
Data recording Maintenance logs
Min/max of instantaneous values
Time stamping
Data logs
Event logs
Alarm logs
Environment
Standards EN/IEC 60947-1
EN/IEC 60092-202
EN/IEC 60255-1
EN/IEC 60947-2
EN/IEC 61010-1
Mounting location Indoor use only
Environmental characteristic Wet location not approved for use conforming to IEC 61010-1
Electromagnetic compatibility Electrostatic discharge immunity test conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Conducted and radiated emissions A conforming to CISPR 22
Overvoltage category IV conforming to IEC 61010-1
Measurement category Category IV conforming to IEC 61010-2-30
Pollution degree 3 conforming to IEC 60947-1
Ambient air temperature for operation -25…70 °C (operating)
-35 °C (for start-up of product)
Relative humidity 95 % at 55 °C conforming to IEC 60068-2-30
Operating altitude <= 2000 m without derating
<= 4000 m with operational voltage derating 600 V AC
<= 5000 m with operational voltage derating 560 V AC
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.0 cm
Package 1 Width 22.0 cm
Package 1 Length 7.0 cm
Package 1 Weight 429.0 g