Home
» Schneider Electric » Low Voltage » Schneider METSEION95030

Schneider METSEION95030

0.00

The price is not final. Please check with the manager!

Schneider Electric PowerLogic™ ION9000T meter, HSTC, DIN mount, no display, HW kit

Ask a Question

Datasheet

Main
RangePowerLogic
Device short nameION95030
Product or component typeEnergy and power quality meter
Device applicationPower monitoring
WAGES metering
Net metering
Medium voltage
High voltage
Metering typeDemand current I1, I2, I3, I4, I5
Peak demand currents
Demand power P, Q, S
Peak demand power PM, QM, SM
Calculated active and reactive energy (+/- W.h, +/- VAR.h)
Complementary
Power quality analysisEN 50160 compliance checking
conforming to IEEE 519 harmonic limit
conforming to IEC 61000-4-30: class A compliance reporting
conforming to IEEE 519 compliance reporting
waveform capture
total demand distortion
total harmonic distortion
up to the 63rd harmonic
up to the 127th harmonic with software
disturbance direction detection
dip, swell and transient
half cycle data acquisition
high-speed transient capture
coincidence disturbance waveform capture
transient detection (100 ns)
Type of measurementVoltage sags and swells
Current sags and swells
Voltage
Current
Frequency
Active and reactive power total
Apparent power total
Active and reactive power per phase
Apparent power per phase
Power factor total
Power factor per phase
Active and reactive energy
Apparent energy
Harmonic distorsion (I THD & U THD)
[Us] rated supply voltage90…480 V AC 45…66 Hz +/- 10 %
90…120 V AC 400 Hz +/- 10 %
110…480 V DC +/- 15 %
Network frequency50 Hz
60 Hz
Ride-through time100 ms 6 cycles at 60 Hz 120 V AC typical
400 ms 24 cycles at 60 Hz 240 V AC typical
1200 ms 72 cycles at 60 Hz 480 V AC typical
[In] rated current1 A
5 A
type of network3P + N + E
Power consumption in VA38 VA at 480 V AC
Maximum power consumption in VA80 VA at 480 V AC
Display typeWithout display
Sampling rate1024 samples/cycle
Measurement current0.01…20 A
input typeVoltage (impedance 5 MOhm)
External CT (impedance 0.3 mOhm)5 x
Measurement voltage57…400 V AC 42…69 Hz between phase and neutral
100…690 V AC 42…69 Hz between phases
10 kV AC transient
Frequency measurement range20…450 Hz
Number of inputs8 digital 30 V AC/60 V DC
Measurement accuracyVoltage +/- 0.1 %
Current +/- 0.1 %
Accuracy classClass 0.1S active energy conforming to IEC 62053-22
Class 0.1 active energy conforming to IEC 61557-12
Class 0.1 active energy conforming to ANSI C12.20
Class 0.5S reactive energy conforming to IEC 62053-24
Class 0.1 current conforming to IEC 61557-12
Class 0.1 voltage conforming to IEC 61557-12
Class 0.1 active power conforming to IEC 61557-12
Class 0.5 power factor conforming to IEC 61557-12
Number of outputs4 digital
2 form C relay
Communication port protocolModbus RTU at 2400…115200 bps – 2-wire
ION at 2400…115200 bps – 2-wire
DNP3 at 2400…115200 bps – 2-wire
Modbus TCP at 10/100 Mbit/s
ION TCP at 10/100 Mbit/s
DNP3 TCP at 10/100 Mbit/s
IEC 61850
Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
DHCP
DNS
DLMS
Communication port supportRS485 2 removable screw terminal block
Port Ethernet10/100BASE-TX 2 RJ45
Communication gatewayEthernet/serial
Time synchronisation protocolGPS
IRIG-B
NTP
SNTP
PTP
Data recordingTime stamping
Min/max of instantaneous values
User-definable data logs
Continuous logging or snapshot
Trending/forecasting
Event logs
Alarm logs
Configuration change
Power outage
User login/logout
Data logs
GPS synchronisation
Sequence of event recording
Memory capacity2 GB
CybersecuritySyslog protocol support
Robust security logs
Port hardening
Enable/disable communication ports
Hardware metrology lock
web servicesViewing of captured waveform
Web page
Pass/fail report for IEEE 519
Pass/fail report for EN 50160
ITIC (CBEMA) curve
SEMI curve
NEMA motor derating curve
Alarm notification by e-mail
TLS 1.2
Push historical data via mail
Ethernet serviceDHCP client
Device Profile Web Services (DPWS)
Rapid Scanning Tree Protocol (RSTP)
FTP/HTTP/HTTPS
Communication serviceCompliant reports
Power quality summary
Energy report
EcoStruxure Power Events Analysis
SMTP e-mail notification
SNMP
Tamperproof of settingsProtected by sealable cover
Mounting supportDIN rail
Electrical insulation classClass III conforming to EN/IEC 62052-11
Isolation voltageIII400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
Width160 mm
Depth135.3 mm
Height160 mm
Net weight1.5 kg
Environment
Electromagnetic compatibilityEMC immunity conforming to IEC 62052-11
EMC immunity conforming to IEC 61326-1
EMC immunity conforming to IEC 61000-6-5
Electrostatic discharge immunity test conforming to IEC 61000-4-2
Immunity to radiated fields conforming to IEC 61000-4-3
Immunity to fast transients conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Immunity to conducted disturbances conforming to IEC 61000-4-6
Immunity to magnetic fields at network frequency conforming to IEC 61000-4-8
Immunity to conducted disturbances – test level: 2…150 kHz conforming to CLC/TR 50579
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Immunity to impulse waves conforming to IEC 61000-4-12
Conducted and radiated emissions conforming to EN 55011
Conducted and radiated emissions class B conforming to EN 55032
Conducted and radiated emissions class B conforming to FCC part 15
Conducted and radiated emissions class B conforming to ICES-003
Surge withstand conforming to ANSI C37.90.1
Surge withstand conforming to IEEE C37.90.1
IP degree of protectionIP65 front:
IP30 rear:
Degree of protectionUL type 12, front
Relative humidity5…95 %
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Installation categoryIII
Operating altitude0…3000 m
StandardsANSI C12.20
ANSI C37.90.1
IEC 61000-4-15
IEC 61000-4-30
IEC 61010-1
IEC 61326-1
IEC 61557-12
IEC 61850
IEC 62052-11
IEC 62052-31
IEC 62053-22
IEC 62053-23
IEC 62053-24
IEC 62586
UL 61010-1
Quality labelsISO 9001
ISO 14000
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height29.5 cm
Package 1 Width26.4 cm
Package 1 Length37.8 cm
Package 1 Weight2.5 kg
Unit Type of Package 2P06
Number of Units in Package 28
Package 2 Height45.0 cm
Package 2 Width80.0 cm
Package 2 Length60.0 cm
Package 2 Weight32.028 kg

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider METSEION95030