Home
» Schneider Electric » Schneider METSEPM8214

Schneider METSEPM8214

1450.27

The price is not final. Please check with the manager!

Schneider Electric PowerLogic PM8000 – PM8214 LV DC – DIN rail mount meter + Remote display – int.

Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Main
Range PowerLogic
Product name PowerLogic PM8000
Device short name PM8214
Product or component type Power meter
Complementary
Power quality analysis conforming to EN 50160: 2010 compliance report
conforming to IEEE 519: 2014 compliance report
conforming to IEC 61000-4-30: class S power quality measurement
up to the 63rd harmonic
harmonic distortion
waveform capture
voltage sag and swell detection
programmablity (logic and math functions)
conforming to IEC 62586 power quality monitoring
Device application Power monitoring
WAGES metering
Type of measurement Current
Voltage
Frequency
Active and reactive power total
Apparent power total
Power factor total
Active and reactive power per phase, rms
Apparent power per phase, rms
Power factor per phase, rms
supply voltage 20…60 V DC +/- 10 %
Network frequency 50 Hz
60 Hz
[In] rated current 5 A
1 A
10 A
Poles description 3P
1P + N
3P + N
Power consumption in W 17 W
Display type Remote LCD display
Display resolution 320 x 240 pixels QVGA
Sampling rate 256 samples/cycle
Measurement current 50…10000 mA
Analogue input type Voltage (impedance 5 MOhm)
Current (impedance 0.3 mOhm)
Measurement voltage 57…400 V AC 42…69 Hz between phase and neutral
100…690 V AC 42…69 Hz between phases
Frequency measurement range 42…69 Hz
Number of inputs 3 digital 30 V AC
3 digital 60 V DC
Measurement accuracy Current +/- 0.1 %
Voltage +/- 0.1 %
Active energy +/- 0.2 %
Accuracy class Class 0.2S active energy conforming to IEC 62053-22
Class 0.2 active energy conforming to ANSI C12.20
Class 0.2 active power conforming to IEC 61557-12
Class 0.5S reactive energy conforming to IEC 62053-24
Class 0.5 power factor conforming to IEC 61557-12
Class 0.2 voltage conforming to IEC 61557-12
Class 0.2 current conforming to IEC 61557-12
Number of outputs 1 pulse
Information displayed Voltage
Current
Frequency
Power
Energy consumption
Harmonic distortion
Communication port protocol Modbus RTU at 115 kbauds – 2-wire
ION at 115 kbauds – 2-wire
DNP3
IEC 61850
Modbus TCP/IP
Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
RSTP 801.1d 2004
Communication port support ETHERNET
Screw terminal block: RS485
communication network type IPv6 (internet protocol)
Data recording Harmonics logs
Waveform logs
Trending/forecasting
Event logs
Alarm logs
Data logs
Sequence of event recording
Sag and swell logs
Min/max of instantaneous values
Time stamping
GPS synchronisation
Memory capacity 512 MB
web services Customizable home page
File upload/download via FTP
File upload/download via SFTP
Web server
Alarm notification by e-mail
Viewing of captured waveform (FTP)
Viewing of captured waveform (web)
HTTPS server
Communication service RSTP support
DHCP
SMTP e-mail notification
NTP time synchronization
SNMP
PTP time synchronization
Cybersecurity Enable/disable communication ports
Robust security logs
Port hardening
Password protection
Syslog protocol support
Mounting mode Clip-on
Flush-mounted
Mounting support DIN rail meter device
Framework remote display
Provided equipment Remote display
Installation category III
Safety Construction III400…690 V conforming to IEC 61010-1:ed. 3
III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
Standards IEC 61557-12
IEC 62052-11
IEC 62053-24
IEC 62053-22
IEEE 1588
IEC 62586-2
IEC 61326-1
Product certifications CE
CULus
N998
Width 90.5 mm
Depth 90.8 mm
Height 90.5 mm
Net weight 528 g
Environment
Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Immunity to impulse waves conforming to IEC 61000-4-12
Conducted and radiated emissions conforming to EN 55022
Conducted and radiated emissions conforming to EN 55011
Conducted and radiated emissions conforming to FCC part 15
Conducted and radiated emissions conforming to ICES-003
Conducted RF disturbances (2…150 Hz) conforming to CLC/TR 50579
Surge withstand conforming to IEEE C37.90.1
IP degree of protection IP30 conforming to IEC 60529
Relative humidity 5…95 %
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Operating altitude 3000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14 cm
Package 1 Width 14 cm
Package 1 Length 37 cm
Package 1 Weight 1.437 kg
Unit Type of Package 2 S03
Number of Units in Package 2 4
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 6.189 kg
Unit Type of Package 3 P06
Number of Units in Package 3 16
Package 3 Height 45 cm
Package 3 Width 80 cm
Package 3 Length 60 cm
Package 3 Weight 33.256 kg