Home
» Schneider Electric » Low Voltage » Schneider METSEPM8244

Schneider METSEPM8244

0.00

The price is not final. Please check with the manager!

Schneider Electric PowerLogic PM8000 – PM8244 DIN rail mount meter + Remote display – int. metering

Ask a Question

Datasheet

Main
RangePowerLogic
Product namePowerLogic PM8000
Device short namePM8244
Product or component typePower meter
Complementary
Power quality analysisconforming to EN 50160: 2010 compliance report
conforming to IEEE 519: 2014 compliance report
conforming to IEC 61000-4-30: class S power quality measurement
up to the 63rd harmonic
harmonic distortion
waveform capture
voltage sag and swell detection
programmablity (logic and math functions)
conforming to IEC 62586 power quality monitoring
Device applicationWAGES metering
Power monitoring
Type of measurementCurrent
Voltage
Frequency
Active and reactive power total
Apparent power total
Power factor total
Active and reactive power per phase, rms
Apparent power per phase, rms
Power factor per phase, rms
supply voltage90…415 V AC 45…65 Hz +/- 10 %
110…415 V DC +/- 10 %
Network frequency50 Hz
60 Hz
[In] rated current10 A
5 A
1 A
Poles description3P
1P + N
3P + N
Power consumption in VA18 VA at 415 V AC
Display typeRemote LCD display
Display resolution320 x 240 pixels QVGA
Sampling rate256 samples/cycle
Measurement current50…10000 mA
Analogue input typeVoltage (impedance 5 MOhm)
Current (impedance 0.3 mOhm)
Measurement voltage57…400 V AC 42…69 Hz between phase and neutral
100…690 V AC 42…69 Hz between phases
Frequency measurement range42…69 Hz
Number of inputs3 digital 30 V AC
3 digital 60 V DC
Measurement accuracyCurrent +/- 0.1 %
Voltage +/- 0.1 %
Active energy +/- 0.2 %
Accuracy classClass 0.2S active energy conforming to IEC 62053-22
Class 0.2 active energy conforming to ANSI C12.20
Class 0.2 active power conforming to IEC 61557-12
Class 0.5S reactive energy conforming to IEC 62053-24
Class 0.5 power factor conforming to IEC 61557-12
Class 0.2 voltage conforming to IEC 61557-12
Class 0.2 current conforming to IEC 61557-12
Number of outputs1 pulse
Information displayedVoltage
Current
Frequency
Power
Energy consumption
Harmonic distortion
Communication port protocolModbus RTU at 115 kbauds – 2-wire
ION at 115 kbauds – 2-wire
DNP3
IEC 61850
Modbus TCP/IP
Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
RSTP 801.1d 2004
Communication port supportETHERNET
Screw terminal block: RS485
communication network typeIPv6 (internet protocol)
Data recordingSequence of event recording
Event logs
Min/max of instantaneous values
Harmonics logs
Alarm logs
GPS synchronisation
Waveform logs
Data logs
Time stamping
Trending/forecasting
Sag and swell logs
Memory capacity512 MB
web servicesCustomizable home page
File upload/download via FTP
File upload/download via SFTP
Web server
Alarm notification by e-mail
Viewing of captured waveform (FTP)
Viewing of captured waveform (web)
HTTPS server
Communication serviceSMTP e-mail notification
RSTP support
NTP time synchronization
DHCP
PTP time synchronization
CybersecurityPassword protection
Syslog protocol support
Port hardening
Robust security logs
Enable/disable communication ports
Mounting modeFlush-mounted
Clip-on
Mounting supportDIN rail meter device
Framework remote display
Provided equipmentRemote display
Installation categoryIII
Safety ConstructionIII400…690 V conforming to IEC 61010-1:ed. 3
III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
StandardsIEC 62053-22
IEC 62053-24
IEC 62052-11
IEC 61557-12
IEEE 1588
IEC 62586-2
IEC 61326-1
Product certificationsCE
CULus
N998
Width90.5 mm
Depth90.8 mm
Height90.5 mm
Net weight528 g
Environment
Electromagnetic compatibilityElectrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Immunity to impulse waves conforming to IEC 61000-4-12
Conducted and radiated emissions conforming to EN 55022
Conducted and radiated emissions conforming to EN 55011
Conducted and radiated emissions conforming to FCC part 15
Conducted and radiated emissions conforming to ICES-003
Conducted RF disturbances (2…150 Hz) conforming to CLC/TR 50579
Surge withstand conforming to IEEE C37.90.1
IP degree of protectionIP30 conforming to IEC 60529
Relative humidity5…95 %
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C
Operating altitude3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.0 cm
Package 1 Width14.0 cm
Package 1 Length37.0 cm
Package 1 Weight1.437 kg
Unit Type of Package 2S03
Number of Units in Package 24
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight6.189 kg
Unit Type of Package 3P06
Number of Units in Package 38
Package 3 Height70.0 cm
Package 3 Width60.0 cm
Package 3 Length80.0 cm
Package 3 Weight20.0 kg

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider METSEPM8244