Schneider LC1F800FW

0.00

The price is not final. Please check with the manager!

Schneider Electric TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 800 A - coil 110...125 V DC

Ask a Question

Datasheet

Main
RangeTeSys
Range of productTeSys F
Product or component typeContactor
Device short nameLC1F
Contactor applicationResistive load
Motor control
Utilisation categoryAC-3
AC-4
AC-1
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC
[Uc] control circuit voltage110…125 V DC
100…120 V AC 40…400 Hz
[Ie] rated operational current1000 A (at <40 °C) at <= 440 V AC AC-1
800 A (at <55 °C) at <= 440 V AC AC-3
Complementary
[Uimp] rated impulse withstand voltage8 kV
[Ith] conventional free air thermal current1000 A (at 40 °C)
Rated breaking capacity6400 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current5500 A 40 °C – 10 s
4600 A 40 °C – 30 s
3600 A 40 °C – 1 min
2600 A 40 °C – 3 min
1700 A 40 °C – 10 min
Associated fuse rating1000 A gG at <= 440 V
800 A aM at <= 440 V
Average impedance0.12 mOhm – Ith 1000 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole120 W AC-1
77 W AC-3
Overvoltage categoryIII
power pole contact composition3 NO
Motor power kW450 kW at 1000 V AC 50/60 Hz (AC-3)
450 kW at 500 V AC 50/60 Hz (AC-3)
475 kW at 660…690 V AC 50/60 Hz (AC-3)
110 kW at 400 V AC 50/60 Hz (AC-4)
450 kW at 380…400 V AC 50/60 Hz (AC-3)
450 kW at 415 V AC 50/60 Hz (AC-3)
450 kW at 440 V AC 50/60 Hz (AC-3)
250 kW at 220…230 V AC 50/60 Hz (AC-3)
Control circuit voltage limitsOperational: 0.85…1.1 Uc (at 55 °C)
Drop-out: 0.3…0.5 Uc (at 55 °C)
Mechanical durability5 Mcycles
Inrush power in W1900 W (at 20 °C)
Hold-in power consumption in W12 W at 20 °C
Maximum operating rate600 cyc/h 55 °C
Operating time40…50 ms opening
60…80 ms closing
Connections – terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) – busbar cross section: 60 x 5 mm
Power circuit: bolted connection
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 58 N.m
Mounting supportPlate
Heat dissipation12 W
motor power range250…500 kW at 200…240 V 3 phases
250…500 kW at 380…440 V 3 phases
110…220 kW at 200…240 V 3 phases
250…500 kW at 480…500 V 3 phases
Motor starter typeDirect on-line contactor
Contactor coil voltage110 V DC standard
125 V DC standard
110 V AC standard
115 V AC standard
120 V AC standard
StandardsEN 60947-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-1
JIS C8201-4-1
Product certificationsABS
RMRoS
CCC
UL
CB
CSA
UKCA
Compatibility codeLC1F
Control circuit typeDC standard
AC at 40…400 Hz
Environment
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
Protective treatmentTH
Ambient air temperature for operation-5…55 °C
Ambient air temperature for storage-60…80 °C
Permissible ambient air temperature around the device-5…55 °C
Height304 mm
Width309 mm
Depth255 mm
Operating altitude3000 m without derating
Net weight18.75 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height44.0 cm
Package 1 Width33.0 cm
Package 1 Length33.0 cm
Package 1 Weight18.975 kg
Unit Type of Package 2P06
Number of Units in Package 24
Package 2 Height77.0 cm
Package 2 Width80.0 cm
Package 2 Length60.0 cm
Package 2 Weight82.76 kg
Contractual warranty
Warranty18 months

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider LC1F800FW