Range | TeSys |
---|---|
Range of product | TeSys F |
Product or component type | Contactor |
Device short name | LC1F |
Contactor application | Resistive load Motor control |
Utilisation category | AC-3 AC-1 AC-4 |
Poles description | 3P |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
[Uc] control circuit voltage | 240 V AC 40…400 Hz |
[Ie] rated operational current | 500 A (at <40 °C) at <= 440 V AC AC-1 400 A (at <55 °C) at <= 440 V AC AC-3 |
[Uimp] rated impulse withstand voltage | 8 kV |
---|---|
[Ith] conventional free air thermal current | 500 A (at 40 °C) |
Rated breaking capacity | 3200 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 3600 A 40 °C – 10 s 2400 A 40 °C – 30 s 1700 A 40 °C – 1 min 1200 A 40 °C – 3 min 1000 A 40 °C – 10 min |
Associated fuse rating | 400 A aM at <= 440 V 500 A gG at <= 440 V |
Average impedance | 0.26 mOhm – Ith 500 A 50 Hz |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
Power dissipation per pole | 65 W AC-1 42 W AC-3 |
Overvoltage category | III |
power pole contact composition | 3 NO |
Motor power kW | 75 kW at 400 V AC 50/60 Hz (AC-4) 200 kW at 380…400 V AC 50/60 Hz (AC-3) 220 kW at 415 V AC 50/60 Hz (AC-3) 250 kW at 440 V AC 50/60 Hz (AC-3) 257 kW at 500 V AC 50/60 Hz (AC-3) 280 kW at 660…690 V AC 50/60 Hz (AC-3) 185 kW at 1000 V AC 50/60 Hz (AC-3) 110 kW at 220…230 V AC 50/60 Hz (AC-3) |
Control circuit voltage limits | Operational: 0.85…1.1 Uc 40…400 Hz (at 55 °C) Drop-out: 0.3…0.5 Uc 40…400 Hz (at 55 °C) |
Mechanical durability | 10 Mcycles |
Inrush power in VA | 1075 VA, 40…400 Hz cos phi 0.9 (at 20 °C) |
Hold-in power consumption in VA | 15 VA, 40…400 Hz cos phi 0.9 (at 20 °C) |
Maximum operating rate | 2400 cyc/h 55 °C |
Operating time | 40…65 ms closing 100…170 ms opening |
Connections – terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) – busbar cross section: 30 x 5 mm Power circuit: lugs-ring terminals 2 cable(s) 150 mm² Power circuit: bolted connection |
Tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
Mounting support | Plate |
Heat dissipation | 14 W |
motor power range | 110…220 kW at 480…500 V 3 phases 110…220 kW at 380…440 V 3 phases 110…220 kW at 200…240 V 3 phases 250…500 kW at 480…500 V 3 phases |
Motor starter type | Direct on-line contactor |
Contactor coil voltage | 240 V AC standard |
Standards | IEC 60947-1 IEC 60947-4-1 EN 60947-4-1 EN 60947-1 JIS C8201-4-1 |
Product certifications | UL BV DNV CB CSA ABS LROS (Lloyds register of shipping) RMRoS RINA UKCA |
Compatibility code | LC1F |
Control circuit type | AC at 40…400 Hz |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 |
---|---|
Protective treatment | TH |
Ambient air temperature for operation | -5…55 °C |
Ambient air temperature for storage | -60…80 °C |
Permissible ambient air temperature around the device | -40…70 °C |
Height | 206 mm |
Width | 213 mm |
Depth | 219 mm |
Operating altitude | 3000 m without derating |
Net weight | 9.1 kg |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 25.5 cm |
Package 1 Width | 24.0 cm |
Package 1 Length | 29.0 cm |
Package 1 Weight | 9.41 kg |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 10 |
Package 2 Height | 77.0 cm |
Package 2 Width | 80.0 cm |
Package 2 Length | 60.0 cm |
Package 2 Weight | 102.7 kg |