Range | ComPact |
---|---|
Range of product | ComPact NSX400…630 |
Product or component type | Trip unit |
Trip unit name | MicroLogic 4.3 AL |
Trip unit technology | Electronic |
Range compatibility | ComPact NSX630 |
Device application | Distribution |
Number of poles | 3P |
Protected poles description | 3t |
Neutral position | Left |
Trip unit protection functions | LSoI |
Protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection |
Trip unit rated current | 570 A at 40 °C |
[Ue] rated operational voltage | 440 V AC 50/60 Hz |
Network type | AC |
Network frequency | 50/60 Hz |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
---|---|
[Ir] long-time protection pick-up adjustment range | 250…570 A |
Long-time protection delay adjustment type tr | Fixed |
[tr] long-time protection delay adjustment range | 11 s at 7.2 x Ir 16 s at 6 x Ir 400 s at 1.5 x Ir |
Thermal memory | 20 minutes before and after tripping |
Short-time protection pick-up adjustment type Isd | Adjustable |
[Isd] Short-time protection pick-up adjustment range | 1.5…10 x Ir |
Short-time protection delay adjustment type tsd | Fixed |
[tsd] Short-time protection delay adjustment range | 0.02 s |
Instantaneous protection pick-up adjustment type Ii | Fixed |
[Ii] instantaneous protection pick-up adjustment range | 6900 A |
Earth-leakage protection | Integrated |
Earth-leakage protection class | Class A |
Earth-leakage protection sensitity adjustment type IΔn | Adjustable |
[IΔn] earth-leakage protection sensitivity adjustment range | 10 A 5 A 500 mA 1 A 3 A 300 mA |
Earth-leakage protection specific mode | OFF using the IΔn rotary switch |
Earth-leakage protection time delay adjustement type Δt | Adjustable |
[Δt] Earth-leakage protection time delay adjustment range | 500 ms 60 ms 1 s 0 ms 150 ms |
Zone selective interlocking ZSI | Without |
Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload Color indicator (yellow) for residual current |
Standards | IEC 60947-2 UL 508 NEMA AB1 EN 60947-2 |
---|---|
Product certifications | EAC CB CCC |
Electrical shock protection class | Class II |
Pollution degree | 3 conforming to IEC 60947-1 |
IP degree of protection | IP40 conforming to IEC 60529 |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -40…85 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 17.400 cm |
Package 1 Width | 21.400 cm |
Package 1 Length | 24.800 cm |
Package 1 Weight | 1.875 kg |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 2 |
Package 2 Height | 30.000 cm |
Package 2 Width | 30.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 4.251 kg |
Warranty | 18 months |
---|