Schneider ATV61QC40N4

0.00

The price is not final. Please check with the manager!

Schneider Electric variable speed drive ATV61Q – 400kW / 600HP – 380…480V – IP20

Ask a Question

Datasheet

Main
Range of productAltivar 61Q
Product or component typeVariable speed drive
Device short nameATV61Q
Product destinationAsynchronous motors
Synchronous motors
Product specific applicationPumping and ventilation machine
Assembly styleWith heat sink
EMC filterIntegrated
Network number of phases3 phases
[Us] rated supply voltage380…480 V – 15…10 %
Supply voltage limits323…528 V
Supply frequency50…60 Hz – 5…5 %
Network frequency limits47.5…63 Hz
Motor power kW355 kW, 3 phases at 380…480 V
400 kW, 3 phases at 380…480 V
Motor power hp600 hp, 3 phases at 380…480 V
Maximum motor cable length100 m shielded cable without motor choke
200 m unshielded cable without motor choke
250 m shielded cable with motor choke
300 m unshielded cable with motor choke
Line current597 A for 480 V 3 phases 355 kW
637 A for 380 V 3 phases 355 kW
644 A for 480 V 3 phases 400 kW / 600 hp
709 A for 380 V 3 phases 400 kW / 600 hp
Complementary
Apparent power419.3 kVA at 380 V 3 phases 355 kW
466.6 kVA at 380 V 3 phases 400 kW / 600 hp
Prospective line Isc50 kA for 3 phases
Continuous output current759 A at 2.5 kHz, 380 V – 3 phases
759 A at 2.5 kHz, 460 V – 3 phases
Maximum transient current910.8 A for 60 s, 3 phases
Speed drive output frequency0.1…500 Hz
Nominal switching frequency2.5 kHz
Switching frequency2…8 kHz adjustable
2.5…8 kHz with derating factor
Speed range1…100 in open-loop mode, without speed feedback
Speed accuracy+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Torque accuracy+/- 15 % in open-loop mode, without speed feedback
Transient overtorque130 % of nominal motor torque +/- 10 % for 60 s
Braking torque<= 125 % with braking resistor
30 % without braking resistor
Asynchronous motor control profileFlux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 2 points
Synchronous motor control profileVector control without sensor, standard
Regulation loopFrequency PI regulator
Motor slip compensationAdjustable
Automatic whatever the load
Can be suppressed
Not available in voltage/frequency ratio (2 or 5 points)
Local signalling1 LED (red) for drive voltage
Output voltage<= power supply voltage
IsolationBetween power and control terminals
Type of cableWith an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC
With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
Electrical connectionTerminal 2.5 mm² / AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR)
Terminal 4 x 185 mm² / 4 x 500 kcmil (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3)
Terminal 8 x 185 mm² / 4 x 500 kcmil (PC/-, PO, PA/+)
Tightening torque41 N.m, 360 lb.in (PC/-, PO, PA/+)
41 N.m, 360 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3)
0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR)
SupplyExternal supply: 24 V DC (19…30 V) – 30 W
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC, +/- 5 %, <10 mA with overload and short-circuit protection
Internal supply: 24 V DC (21…27 V), <200 mA with overload and short-circuit protection
Analogue input number2
Analogue input typeAI2 software-configurable voltage: 0…10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits
AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign
AI2 software-configurable current: 0…20 mA, impedance: 242 Ohm, resolution 11 bits
Sampling duration2 ms +/- 0.5 ms (LI6)if configured as logic input – discrete input
2 ms +/- 0.5 ms (AI1-/Al1+) – analog input
2 ms +/- 0.5 ms (Al2) – analog input
2 ms +/- 0.5 ms (AO1) – analog output
2 ms +/- 0.5 ms (LI1…LI5) – discrete input
Accuracy+/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C
+/- 0.6 % (AI2) for a temperature variation 60 °C
+/- 1 % (AO1) for a temperature variation 60 °C
Linearity error+/- 0.15 % of maximum value (AI1-/Al1+)
+/- 0.15 % of maximum value (AI2)
+/- 0.2 % (AO1)
Analogue output number1
Analogue output typeAO1 software-configurable current: 0…20 mA, impedance: 500 Ohm, resolution 10 bits
AO1 software-configurable voltage: 0…10 V DC, impedance: 470 Ohm, resolution 10 bits
AO1 software-configurable logic output 10 V 20 mA
Discrete output number2
Discrete output typeConfigurable relay logic: (R1A, R1B, R1C) NO/NC – 100000 cycles
Configurable relay logic: (R2A, R2B) NO – 100000 cycles
Response timeR1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 ms
R2A, R2B <= 7 ms, tolerance +/- 0.5 ms
<= 100 ms in STO (Safe Torque Off)
Minimum switching current3 mA at 24 V DC for configurable relay logic
Maximum switching current2 A at 250 V AC on inductive load – cos phi = 0.4 – L/R = 7 ms (R1, R2)
2 A at 30 V DC on inductive load – cos phi = 0.4 – L/R = 7 ms (R1, R2)
5 A at 250 V AC on resistive load – cos phi = 1 – L/R = 0 ms (R1, R2)
5 A at 30 V DC on resistive load – cos phi = 1 – L/R = 0 ms (R1, R2)
Discrete input number7
Discrete input typeLI1…LI5: programmable 24 V DC with level 1 PLC, impedance: 3500 Ohm
LI6: switch-configurable 24 V DC with level 1 PLC, impedance: 3500 Ohm
LI6: switch-configurable PTC probe 0…6, impedance: 1500 Ohm
PWR: safety input 24 V DC, impedance: 1500 Ohm
Discrete input logicNegative logic (sink) (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (LI1…LI5), > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (LI1…LI5), < 5 V (state 0), > 11 V (state 1)
Acceleration and deceleration rampsLinear adjustable separately from 0.01 to 9000 s
Automatic adaptation of ramp if braking capacity exceeded, by using resistor
S, U or customized
Braking to standstillBy DC injection
Protection typeAgainst exceeding limit speed: drive
Against input phase loss: drive
Break on the control circuit: drive
Input phase breaks: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Overvoltages on the DC bus: drive
Power removal: drive
Short-circuit between motor phases: drive
Thermal protection: drive
Motor phase break: motor
Power removal: motor
Thermal protection: motor
Dielectric strength3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Insulation resistance> 1 mOhm 500 V DC for 1 minute to earth
Frequency resolutionAnalog input: 0.024/50 Hz
Display unit: 0.1 Hz
communication port protocolCANopen
Modbus
Connector type1 RJ45 (on front face) for Modbus
1 RJ45 (on terminal) for Modbus
Male SUB-D 9 on RJ45 for CANopen
Physical interface2-wire RS 485 for Modbus
Transmission frameRTU for Modbus
Transmission rate4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal
9600 bps, 19200 bps for Modbus on front face
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
Data format8 bits, 1 stop, even parity for Modbus on front face
8 bits, odd even or no configurable parity for Modbus on terminal
Type of polarizationNo impedance for Modbus
Number of addresses1…127 for CANopen
1…247 for Modbus
Method of accessSlave CANopen
Type of coolingWater cooled
Cooling fluid typeIndustrial water
Water-glycol mixture
Clean water
operating temperature water5…55 °C
Thermal losses6700 W 100 % of line current for area of liquid cooling (power part)
1610 W 100 % of line current for area of air cooling (control part)
Flow velocity range24
Pressure drop2 bar
volume of cooling water0.7 l
Operating positionVertical +/- 10 degree
Net weight300 kg
Option cardCommunication card for APOGEE FLN
Communication card for BACnet
Communication card for CC-Link
Communication card for DeviceNet
Communication card for EtherNet/IP
Communication card for Fipio
Communication card for Interbus-S
Communication card for LonWorks
Communication card for METASYS N2
Communication card for Modbus Plus
Communication card for Modbus TCP
Communication card for Modbus/Uni-Telway
Communication card for Profibus DP
Communication card for Profibus DP V1
Controller inside programmable card
I/O extension card
Multi-pump card
Width1110 mm
Height1150 mm
Depth377 mm
Environment
Ambient air temperature for operation-10…50 °C (without derating)
50…60 °C (with derating factor)
Ambient air temperature for storage-25…70 °C
Operating altitude<= 1000 m without derating
1000…3000 m with current derating 1 % per 100 m
Electromagnetic compatibilityConducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Pollution degree3 conforming to EN/IEC 61800-5-1
3 conforming to UL 840
IP degree of protectionIP00 conforming to EN/IEC 60529
IP00 conforming to EN/IEC 61800-5-1
IP30 on side parts conforming to EN/IEC 60529
IP30 on side parts conforming to EN/IEC 61800-5-1
IP30 on the front panel conforming to EN/IEC 60529
IP30 on the front panel conforming to EN/IEC 61800-5-1
IP41 on upper part conforming to EN/IEC 60529
IP41 on upper part conforming to EN/IEC 61800-5-1
Vibration resistance0.6 gn (f= 10…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f= 3…10 Hz) conforming to EN/IEC 60068-2-6
Shock resistance4 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Noise level70 dB conforming to 86/188/EEC
StandardsEN 55011 class A group 2
EN 61800-3 environments 2 category C3
EN/IEC 61800-5-1
UL Type 1
EN 61800-3 environments 1 category C3
IEC 60721-3-3 class 3C2
EN/IEC 61800-3
Product certificationsGOST
NOM 117
DNV
CSA
C-Tick
UL
MarkingCE
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height53.0 cm
Package 1 Width116.0 cm
Package 1 Length145.0 cm
Package 1 Weight235.0 kg
Contractual warranty
Warranty18 months

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider ATV61QC40N4