Home
» Schneider Electric » Low Voltage » Schneider IMDIFL12MC

Schneider IMDIFL12MC

0.00

The price is not final. Please check with the manager!

Schneider Electric VIGILOHM ADVANCED 12 CHANNEL FAULT LOCATOR WITH MODBUS – 100-440VAC/DC

Ask a Question

Datasheet

Main
RangeVigilohm
Device short nameIFL12MC
Product or component typeInsulation fault locator
Device applicationMarine application
Standard environment application
electrical circuit typeLarge or highly disturbed network
Electrical circuit typePower circuit
Control/command circuit
Earthing systemIT
languageSpanish
German
Italian
Russian
French
Chinese
English
Portuguese
Complementary
Network rated voltage0…480 V – AC at 45…440 Hz (device connected to phase)
0…830 V – AC at 45…440 Hz (device connected to neutral)
0…480 V – DC
Number of channels12
Data recordingAlarm logs
Type of measurementHistory of alarms
Network insulation resistance – measurement range: 200 Ohm…250 kOhm
Earth leakage capacitance – measurement range: 0.1…15 µF
Local signallingYellow indicator light: insulation fault
Yellow flashing indicator light: communication
Green/red indicator light: product status
Green indicator light: satisfactory insulation
Yellow flashing indicator light: transient fault
Threshold settingAlarm: 200 Ohm…200 kOhm
Time delay range0…120 min for signalling circuit
alarm per channelAlarm threshold: settable per feeder
Accuracy+/- 15 %
Response time<= 5 s
auxiliary supply voltage100…440 V DC +/- 15 %
100…440 V AC 45…65 Hz +/- 15 %
Power consumption in VA26 VA
Power consumption in W10 W
Test functionAuto test at start and every 5h
Remote test
Manual
output contact1 C/O standard or fail-safe
breaking capacity250 V – AC at 6 A
48 V – DC at 1 A
communication port protocolModbus
Communication port supportRS485
Display typeDigital display
Mounting modeFlush-mounted
Clip-on
Mounting supportPanel
DIN rail
Mounting positionVertical
Horizontal
Connections – terminalsPower supply: removable screw terminal block0.2…2.5 mm²
Output relay: removable screw terminal block0.2…2.5 mm²
Toroids inputs: removable screw terminal block0.2…1.5 mm²
Communication: removable screw terminal block0.2…2.5 mm²
Voltage inputs: removable screw terminal block0.2…2.5 mm²
MaterialThermoplastic
Overvoltage categoryIII
Net weight0.5 kg
Cut-out dimensions92 x 104 mm
Height110 mm
Width108 mm
Depth59 mm
Environment
IP degree of protectionCase: IP20
Front face: IP54
Environmental characteristicExposure to damp heat not in service conforming to IEC 60068-2-30
Exposure to damp heat in service conforming to IEC 60068-2-56
Salt mist conforming to IEC 60068-2-52
Operating altitude<= 3000 m
Pollution degree2
Relative humidity5…92 %
Type of installationIndoor
StandardsIEC 60364-4-41
IEC 61010-1
IEC 60364-5-51
IEC 61557-9
Product certificationsCE
DNV-GL
EAC
UL
cULus
Ambient air temperature for operation-25…55 °C
Ambient air temperature for storage-40…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.7 cm
Package 1 Width18.2 cm
Package 1 Length13.5 cm
Package 1 Weight550.0 g
Unit Type of Package 2S03
Number of Units in Package 28
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight5.2 kg

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider IMDIFL12MC