Home
» Sick » Sick AFM60B-S4TA016384

Sick AFM60B-S4TA016384

587.11

The price is not final. Please check with the manager!
SKU: AFM60B-S4TA016384 Categories: , , Brand:
  • High-resolution absolute encoders with up to 30 bits (AFM60) or up to 18 bits (AFS60)
  • Face mount flange, servo flange, blind or through hollow shaft
  • SSI, SSI + Incremental or SSI + Sin/Cos interface
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1058758
Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
Power consumption: 0.5 W (without load)
CW/CCW (counting sequence when turning): L-active (L &;8801; 0 – 1,5 V, H &;8801; 2,0 – Us V)
Moment of inertia of the rotor: 6.2 gcm²
Maximum output frequency: 600 kHz
Electrical interface: Connector M23, 12-pin, radial
SET (electronic adjustment): H-active (L &;8801; 0 – 1,5 V, H &;8801; 2,0 – Us V)
Operating voltage range: 4.5 V DC … 32 V DC
Start up torque: 0.5 Ncm (20 °C)
Shaft diameter: 10 mm
Maximum operating speed: 9,000 /min
Measuring step: 90 ° elektrisch / Strichzahl
Repeat accuracy: 0.002 °
Load current max.: 30 mA
Max. number of revolutions: 4,096
Bearing lifetime: 3.0 x 10^9 revolutions
Operating torque: 0.3 Ncm (20 °C)
Clock frequency: 2 MHz
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Mechanical interface: Solid shaft with flat, Face mount flange
Storage temperature range: -40 °C … 100 °C, without package
MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1)
Permissible relative humidity: 90 % (condensation of the optical scanning not permitted)
Mass: 0.26 kg
Interface signals: A, B: digital differential, Clock +, Clock -, Data +, Data-
Measuring step deviation: ± 0.01 °
Resistance to vibration: 30 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)
Resolution power: 16,384 x 4,096
Max. number of steps per revolution: 16,384
Max. angular acceleration: 500,000 rad/s²
Resolution: 14 bit x 12 bit
Permissible Load capacity of shaft: 40 N (axial), 80 N (radial)
Initialization time: 50 ms
Reference signal, position: 90 °, electronically, gated with A and B
Resistance to shocks: 70 g (according to EN 60068-2-27)
Error limits: ± 0.05 °
Working temperature range: -30 °C … 100 °C