Home
» Sick » Sick ARS60-ADM04096

Sick ARS60-ADM04096

680.83

The price is not final. Please check with the manager!
SKU: ARS60-ADM04096 Categories: , , Brand:
  • Absolute singleturn encoder
  • Resolution: up to 15 bits (32,768 increments)
  • Electrical interface: SSI with gray code type or gray capped
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1033904
Start up torque: 2.2 Ncm
Measuring step: 360 ° /number of lines
Error limits: 0.035 ° (binary number of steps)
0.046 ° (non-binary number of steps)
Operating torque: 1.6 Ncm
Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm
Resolution power: 4,096 x 1
Shaft diameter: 6 mm
8 mm
10 mm
12 mm
14 mm
15 mm 1/4 “
3/8 “
1/2 “
Max. angular acceleration: 500,000 rad/s²
Resistance to vibration: 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)
Max. number of steps per revolution: 4,096
Resistance to shocks: 50 g (according to EN 60068-2-27)
Bearing lifetime: 3.6 x 10^9 revolutions
Electrical interface: Cable, 11-pin, radial, 5 m
Repeat accuracy: 0.005 °
Initialization time: 80 ms
Operation of zero-set: ≥ 100 ms
Working temperature range: -20 °C … 85 °C
Measuring step deviation: 0.005 °, 0.016 °
Maximum operating speed: 3,000 /min
Storage temperature range: -40 °C … 100 °C
Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm
Enclosure rating: IP 64 (according to IEC 60529)
Operating power consumption (no load): 60 mA
Permissible relative humidity: 90 % (condensation of the optical scanning not permitted)
Mechanical interface: Through hollow shaft
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Max. number of revolutions: 1
Operating voltage range: 10 V DC … 32 V DC
MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1)