Home
» Sick » Sick ATM90-ATL12X12

Sick ATM90-ATL12X12

0.00

The price is not final. Please check with the manager!
SKU: ATM90-ATL12X12 Categories: , , Brand:
  • Extremely rugged, tried-and-tested absolute multiturn encoder with a resolution of up to 26 bits
  • Mechanical interface: through hollow shaft with shallow installation depth
  • Zero-set and preset functions via hardware or software
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1030032
CW/CCW (counting sequence when turning): L-active (L &;8801; 0 – 1,5 V, H &;8801; 2,0 – Us V)
Start up torque: 0.5 Ncm
Resolution: 12 bit x 12 bit
Operating torque: 0.4 Ncm
Parameterising data: Number of revolutions, Code type, Electronic adjustment, Number of steps per revolution
Mechanical interface: Through hollow shaft
Connection type: Cable, 12-pin, radial, 3 m
Shaft material: Stainless steel
Working temperature range: -20 °C … +70 °C
Max. number of steps per revolution: 4,096
Max. number of revolutions: 4,096
Resolution power: 4,096 x 4,096
Enclosure rating: IP 65 (according to IEC 60529), with shaft seal
Moment of inertia of the rotor: 153.77 gcm²
MTTFd: mean time to dangerous failure: 150 a (EN ISO 13849-1)
Max. angular acceleration: 600,000 rad/s²
SET (electronic adjustment): H-active (L &;8801; 0 – 4,7 V, H &;8801; 10 – Us V)
Code type: Binary, Gray
Housing material: Die-cast aluminum
Permissible relative humidity: 98 %
Storage temperature range: -40 °C … +100 °C, without package
Shaft diameter: 12 mm
Repeat accuracy: 0.1 °
Resistance to vibration: 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)
Flange material: Aluminum
Bearing lifetime: 3.6 x 10^9 revolutions
Code sequence: CW/CCW
Interface signals: Clock +, Clock -, Data +, Data-, Programming interface: RS-422
Operating voltage range: 10 V … 32 V
Electrical interface: SSI
Measuring step: 0.043 °
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Power consumption max. without load: 0.8 W
Clock frequency: 1 MHz
Error limits: ± 0.25 °
Initialization time: 1,050 ms
Resistance to shocks: 100 g, 6 ms (according to EN 60068-2-27)