Part Number 1030040
Resistance to vibration: 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)
Clock frequency: 1 MHz
Measuring step: 0.043 °
Repeat accuracy: 0.1 °
Max. number of revolutions: 4,096
Max. angular acceleration: 600,000 rad/s²
Power consumption max. without load: 0.8 W
Permissible relative humidity: 98 %
Storage temperature range: -40 °C … +100 °C, without package
Parameterising data: Number of revolutions, Code type, Electronic adjustment, Number of steps per revolution
Electrical interface: SSI
Code type: Binary, Gray
Working temperature range: -20 °C … +70 °C
Enclosure rating: IP 65 (according to IEC 60529), with shaft seal
Moment of inertia of the rotor: 153.77 gcm²
CW/CCW (counting sequence when turning): L-active (L &;8801; 0 – 1,5 V, H &;8801; 2,0 – Us V)
Operating voltage range: 10 V … 32 V
SET (electronic adjustment): H-active (L &;8801; 0 – 4,7 V, H &;8801; 10 – Us V)
Bearing lifetime: 3.6 x 10^9 revolutions
Interface signals: Clock +, Clock -, Data +, Data-, Programming interface: RS-422
Mechanical interface: Through hollow shaft
Shaft material: Stainless steel
Initialization time: 1,050 ms
Code sequence: CW/CCW
Error limits: ± 0.25 °
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
MTTFd: mean time to dangerous failure: 150 a (EN ISO 13849-1)
Resolution: 12 bit x 12 bit
Resolution power: 4,096 x 4,096
Operating torque: 0.4 Ncm
Max. number of steps per revolution: 4,096
Housing material: Die-cast aluminum
Resistance to shocks: 100 g, 6 ms (according to EN 60068-2-27)
Shaft diameter: 16 mm
Connection type: Cable, 12-pin, radial, 3 m
Flange material: Aluminum
Start up torque: 0.5 Ncm